American Standard 2422L/LA/V/VA Installation Manual Download Page 13

753737-100 Rev. C

13

DRAIN CONNECTION AND SYSTEM TEST

Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions.  

Tighten all drain joints securely.  Check the pump couplings and make sure they are hand-tight.  Clean the whirlpool and fill with 

water to a point " above the top of the highest jet.  Recheck the pump couplings and make certain that they are not leaking.  

(Although the pump couplings are factory tightened and inspected, some loosening may have occurred during transit.)  Make sure 

the whirlpool is connected to the electrical supply and turn the whirlpool on.  Check for leaks around all piping connections while the 

whirlpool is running.

POST INSTALLATION CLEAN-UP

Remove all construction debris from bath.  Tile grout can be removed with a wooden popsicle stick or tongue depressor.  Do not use 

wire brushes or any other metal implement on bath surface.

Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent.  Stubborn dirt or stains 

may be removed using granular Spic and Span® mixed with water.

Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.

AFTERCARE and CLEANING

• The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and  

   maintenance.

• Always fill the tub with temperate water. Excessively hot water may cause surface damage

• Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.

• Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray or      

   concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner, or    

   cleaning products in aerosol cans.

 

HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.

• Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other surface blemishes.

• Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses  

   its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and 

   waxing with a "liquid wax."

 Do not wax areas where you walk or stand.

• Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into  

   contact with the surface.

• Clean the surrounding surface immediately after using caustic drain cleaners.

• Burning cigarettes will damage the surface.

• Should damage to the fixture occur, repairs can be made quickly and easily. 

   Your distributor or builder can provide details.

• Do not permit drain cleaner to enter the circulation system.

CIRCULATION SYSTEM CLEANING-PURGING PROCEDURES

STEP 1. 

Once every month purge and clean the circulating system. Fill whirlpool with warm water and add two teaspoons  

 

               of dishwasher detergent and one-half cup of house hold bleach.

STEP 2. 

Activate whirlpool system in accordance with operating instructions or two minutes.

STEP 3. 

Drain and refill whirlpool with cool water and circulate for additional five minutes.

STEP 4. 

Drain whirlpool completely.

Summary of Contents for 2422L/LA/V/VA

Page 1: ...tions and cautions MODEL 2422L LA V VA 5 x 32 MODEL 6060L V CORNER MODEL 2771L LA V VA 5 x 36 MODEL 2645L LA V VA OVAL MODEL 7236L LA V VA 6 x 36 MODEL 2425L V LHO 5 x 32 IA LHO MODEL 2425L V RHO 5 x...

Page 2: ...ional Components Page Specifications Page 5 Roughing in Reference Page Framing and Support Instructions Page Mounting Instructions Page 10 Electrical Connections Page 11 0 0L V Corner EZ Install Heate...

Page 3: ...ribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupte...

Page 4: ...ment Plaster Grout General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection an...

Page 5: ...H 5 mm 1 1 L 15 mm 0 W 1 mm 3 H 5 mm 1 1 L 1 mm 7 W 1 mm 3 H 5 mm 1 1 L 15 mm 0 W 13mm 3 H 5 1mm 0 1 L 1 7 mm W 1 mm 3 H 50 mm 1 3 L 1 mm 7 W 111 mm H 55 mm L 1 7 mm W 1 mm 3 H 1 mm 1 L 1 mm 7 W 1 1...

Page 6: ...LHO MODEL 2425L V LHO shown 5 x 32 IA RHO MODEL 2425L V RHO 0 15 mm 3 1 mm 3 7 mm 7 1 1 1mm 15 mm 11 7 mm 13 3 3 mm CUT OUT IN FLOOR FOR DRAIN 5 x 36 MODEL 2771L LA V VA 7 1 mm 3 1 mm 7 3 1 7mm 11 7 m...

Page 7: ...AIN OUTLINE OF CUTOUT 2159mm 85 1080 mm 42 1 2 C L 1524mm 60 1076mm 42 3 8 1080mm 42 1 2 PUMP C L OF DRAIN OUTLET 5X42 MODEL 2805L 1524mm 60 INTEGRAL FITTING DECK 762mm 30 1067mm 42 PROVIDE ACCESS TO...

Page 8: ...m 1 JETS CUTOUT IN FLOOR FOR DRAIN PUMP FINISHED WALL 1 mm 3 mm C L OF DRAIN AIR VALVES PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS CADET 6 x 42 MODEL 2774L LA C L OF DRAIN RECOMMENDED F...

Page 9: ...e whirlpool following the drain installation instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the rou...

Page 10: ...il Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result 5 Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the tr...

Page 11: ...electrical codes Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 50 100 115V Power Line 150 200 12 10 8 8 The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The cir...

Page 12: ...e heater will help maintain the temperature of the water in the bath Pressure Switch The heater is equipped with a preset pressure switch The pump must be running with water flowing in the whirlpool t...

Page 13: ...se and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrat...

Page 14: ...dealers installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specif...

Page 15: ...UJPO JO UIJT NBOVBM JT CBTFE PO UIF MBUFTU QSPEVDU JOGPSNBUJPO BWBJMBCMF BU UIF UJNF PG QVCMJDBUJPO 4 NFSJDBT OD SFTFSWFT UIF SJHIU UP NBLF DIBOHFT JO QSPEVDU DIBSBDUFSJTUJDT QBDLBHJOH PS BWBJMBCJMJUZ...

Page 16: ...JOUFOEFE VTF BT EFTDSJCFE JO UIJT NBOVBM P OPU VTF BOZ BUUBDINFOUT OPU SFDPNNFOEFE CZ NFSJDBO 4UBOEBSE 5IF VOJU NVTU CF DPOOFDUFE POMZ UP B TVQQMZ DJSDVJU UIBU JT QSPQFSMZ QSPUFDUFE CZ B HSPVOE GBVMU...

Page 17: ...BHSBN CFMPX P OPU GJMM XIJSMQPPM NPSF UIBO GVMM QSJPS UP UIF VTFS DPNQMFUFMZ JNNFSTJOH UIFNTFMWFT JOUP VOJU 4UBSU 8IJSMQPPM 1VTI PO DFOUFS PG CVUUPO VUUPO XJMM EFQSFTT BOE XIJSMQPPM XJMM TUBSU 4UPQ 8I...

Page 18: ...NPTU EFTJSBCMF DPOEJUJPO 4NBMM FU BSHF FU 4PGUFS BTTBHF DPVOUFS DMPDLXJTF PSF 7JHPSPVT BTTBHF DMPDLXJTF 4PGUFS BTTBHF DPVOUFS DMPDLXJTF PSF 7JHPSPVT BTTBHF DMPDLXJTF JGFUJNF SBJO PEFM SFRVJSFE PO PEFM...

Page 19: ...FS UP UIF IFBUFS 8IJSMQPPM CBUI JT OPX SFBEZ UP VTF OEJDBUPS JHIU 5IF MJHIU UVSOT PO XIFO UIF IFBUFS JT PQFSBUJOH 1SFTTVSF 4XJUDI 5IF IFBUFS JT FRVJQQFE XJUI B QSFTFU QSFTTVSF TXJUDI 5IJT TXJUDI XJMM...

Page 20: ...ATE 15 AMP GFCI OUTLET RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP MOTOR FRAME LUG AND FROM PUMP MOTOR LUG TO APPROVED GROUND AS SHOWN PUMP MOTOR TO GROUND SECOND COPPER CONDUCTO...

Page 21: ...OBM DPOTVNFS QVSDIBTFS 5IJT XBSSBOUZ TIBMM POMZ CFDPNF FGGFDUJWF VQPO SFDFJQU CZ NFSJDBO 4UBOEBSE PG B DPNQMFUFMZ GJMMFE PVU 8BSSBOUZ 3FHJTUSBUJPO BSE FWJEFODJOH QSPPG PG QVSDIBTF 5 4 8 33 5 4 70 5 44...

Reviews: