background image

12

4

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

10

TEST INSTALLED FITTING

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in SINK. If DRAIN STOPPER 

(5)

does not seal properly, please refer to Troubleshooting
section in these instructions.

Release POP-UP KNOB 

(4)

 down and check all drain

connections and

 "P" trap

 for leaks.     Tighten

if necessary.

With HANDLES 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2)

 and check all connections for leaks.

Ensure that AERATOR 

(3)

 is tightened completely.

Operate HANDLES 

(1)

 to allow water flow.

M 9 6 8 8 7 6   R e v.   1 . 2        

3

2

1

5

2

4

“P” TRAP

WASTE

OUTLET

11

SERVICE

1

2

3

5

6

4

If Faucet Drips Proceed As Follows:

To Clean Aerator:

Turn VALVE to OFF position.

To Change Direction Of Handle Rotation, 
Proceed As Follows:

If spout drips, operate HANDLES 

(1)

 several times from OFF to ON position. Do not force-handles they turn only 90˚.

AERATOR 

(6)

 may accumulate dirt causing distorted and 

reduced water flow. Remove AERATOR 

(6)

 and rinse clean.

FLAT

Turn VALVE to OFF position.

Loosen SET SCREW 

(2)

 and pull HANDLE 

(1)

 off. Remove 

ADAPTER SCREW 

(4)

 and pull ADAPTER 

(3) 

off VALVE STEM 

(5)

.

Turn ADAPTER 

(3)

 90˚ so that flat within ADAPTER 

(3)

 catches 

a different flat on the VALVE STEM 

(5)

.

Replace ADAPTER 

(3)

, ADAPTER SCREW 

(4)

 and HANDLE 

(1)

Tighten SET SCREW 

(2)

Reviews: