background image

M 9 6 5 117   R E V.  1. 1

INSTALL THE R120SS VALVE BODY

1

When finished tiling the wall, remove PLASTER GUARD.

Remove cap from tub supply pipe.

R120SS

When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS

(IF PRESENT). When finished soldering, flush valve body, replace cartridges, check stops

(if present) and plaster guard to continue installation. Use thread sealant or Teflon tape

on threaded connections.

NOTE

IMPORTANT

See Roughing-in diagram before starting.
Connections are:
  1/2" copper sweat for sweat inlets
  1/2" copper sweat for sweat tub and shower outlets

REFER TO INSTALLATION INSTRUCTIONS (M968387) SUPPLIED WITH VALVE BODY FOR

COMPLETE INSTALLATION AND REPAIR PART INFORMATION. 

REFER TO INSTALLATION INSTRUCTIONS (M968763) SUPPLIED WITH VALVE

TRIM KIT FOR COMPLETE INSTALLATION AND REPAIR PART INFORMATION. 

NOTE

1/2" SWEAT PLUG

MAKE ALL CONCEALED PIPING CONNECTIONS

INSTALL VALVE TRIM

3

4

See Roughing-in diagram before starting.

Make Hot and Cold supply connections to the VALVE BODY. Inlet and outlet connections to the valve body are 1/2" copper sweat.

Make Tub Filler connection from DIVERTER. (Use the port with the BATH TUB picture). DIVERTER IS 1/2" NPT. TUB SPOUT

connection is 1/2" copper for SLIP-ON SPOUT.

Make the connections for the HAND SHOWER. The HAND SHOWER connections are 1/2" NPT.

For support, use PIPE BRACES secured to wooden braces. Cap off HAND SHOWER and TUB SPOUT FILLER PIPE.

With the R120SS VALVE turned off, turn on water supplies. Check for leaks.

Finish all wall construction.

CAP

PLASTER GUARD

INSTALL THE R420 TWO-WAY DIVERTER

2

TWO-WAY

DIVERTER

REFER TO INSTALLATION INSTRUCTIONS (50321) SUPPLIED WITH DIVERTER FOR

COMPLETE INSTALLATION AND REPAIR PART INFORMATION. 

The reverse side of the body is marked with arrows.

CAUTION: Do not solder near the VALVE. Damage to the SEAL may occur. Do not seal

any outlets. The DIVERTER cannot be used as a stop valve. Use thread sealant or sealing

tape on threaded connections.

NOTE

IMPORTANT

1/2" NPT INLET

1/2" NPT

SHOWER

1/2" NPT HAND

SHOWER

See Roughing-in diagram before starting. The port with the BATH TUB picture is the high flow.

The DIVERTER can be installed with the inlet rotated in any position.

All connections are 1/2" NPT.

For proper positioning the finished wall must be within the side of PLASTER GUARD.

Connect the R420 TWO-WAY DIVERTER to the R120SS VALVE BODY. 