Summary of Contents for CO800

Page 1: ...AMERICAN 1 HOME HEALTH AND SAFf3Y PRODUCTSTM CARBON MONOXIDE SMARTHOME COM TM 1 800 SMART HOME 949 221 9200 http www smarthome com...

Page 2: ...seen The presence of carbon monoxide inhibits the blood s capacity to transport oxygen throughout the body which can eventually lead to br tin damage In any enclosed space home office recreational veh...

Page 3: ...lls and in any gasoline powered vehicle or engine e g generator set or lawn mower Tobacco smoke also adds CO to the air you breathe When properly installed and maintained your natural gas nace and hot...

Page 4: ...heat exchangers Collapsed or blocked chimneys or flues dislodged disconnected or damaged vents Downdraft in chimneys or flues this can also be caused by very long or circuitous flue runs improper loc...

Page 5: ...home off ice L Clogged Chimney I Automobile and Garage Gas or Kerosene Heater Gas Water Heater Gas or Oil Furnace Wood or Gas Fireplace s i t Gas Appliances Cigarette Smoke 7 SMARTHOME COM TM 1 800 SM...

Page 6: ...ld so that you know what to look for Extreme Exposure A C Unconsciousness convulsions cardiorespiratory failure death Medium Exposure D G Severe throbbing headache drowsiness confusion vomiting fast h...

Page 7: ...ur home In the figure below are suggested locations in the home The electronic sensor detects Do not place the detector in the following areas Where the temperature may drop below 40 F 44 C or exceed...

Page 8: ...ease allow one hour for your detector to initialize after placement in electrical socket Do not use detector in an outlet that is controlled by a wall switch If you have a double outlet plug the detec...

Page 9: ...O CO910 The detector should be installed vertically If your outlet has a horizontal orientation simply rotate the plug on the back of the unit 90 and install RotatePlug I I Install in Outlet 12 SMARTH...

Page 10: ...Simply attach your unit to any standatd 120 Volt wiring system utilizing the ho wires and one of the electrical federal ctricaf and building code standards at all times Mount your Carbon Monoxide Dete...

Page 11: ...re wire is exposed outside the con nector Connect the black wire live from the junction box to the black wire of the Detector using a twist on wire connector and the same method as above White wire Bl...

Page 12: ...ore servicing the detector To remove the detector from its mounting plate the locking mechanism located in the top right corner must be released as you slide the detector unit upwards This will expose...

Page 13: ...Monoxide Detector is designed to do a continuous self diagnostic check of its micro processing circuitry when in use A malfunctioning unit is indicated by a continuing intermittent single beep and fla...

Page 14: ...ofdust Test Resetbutton Testthe detector by pressing the Test Reset button once a month In addition a Carbon Monoxide Detector Test Kit is available to test the detector in a true carbon monoxide envi...

Page 15: ...awer It is rn fur this light to be on while the danor is 0 W i rn F d This lights up red when the will flash red when the low normal for this light tu turn Test Reset button fidi ahrm soundsand level...

Page 16: ...concentrations your LED Display will show the ppms present in increments of 10 starting at 50 i e 50 60 70 etc Beyond 150 ppm the unit will show H I which indicates high or dangerous levels of CO It...

Page 17: ...A What shouldyou do iifthe Alarm sounds If 1 2 3 SMARTHOME COM TM 1 800 SMART HOME 949 221 9200 http www smarthome com...

Page 18: ...22 What to do afier a carbon maxkde problem has been corrected After a carbon monoxide problem has been corrected detector by pushing the Test Reset button as per the on Page 16 reset your instructio...

Page 19: ...a location with fresh air Do a head count to check that all persons are accounted for Do not re enter your home until the home has been aired out and the problem corrected by a qualified technician or...

Page 20: ...22 What to do after a carbon monoxide problem has been corrected After a carbon monoxide problem has been corrected detector by pushing the Tit Reset button as per the on Page 16 reset your instructi...

Page 21: ...es at exposures of 100 ppm l In less than 35 minutes at exposures of 200 ppm l In less than 15 minutes at exposures of 400 ppm The Low Level Warning l Low levelwarning activates in less than PO minute...

Page 22: ...s not been investigated for carbon monoxide detection below 60 ppm Individuals with medical conditions such as pregnancy respiratory or cardiac diseases and the very elderly may consider using more se...

Page 23: ...nt chimney deterioration will increase the risk of chimney blockage draft failure and the associated release of combustion products into the house Qualified contractors and inspection by the gas compa...

Page 24: ...not blocked nests Using other equipment that consumes or exhausts by insulation leaves or bird household air If you use exhaust fans a fireDlace or other fuel burning I I heaters or stoves Run exhaus...

Page 25: ...our fuel burning equipment checked periodically for safety and efficiency by a qualified service technician If you are adding a wood or coal burning stove to a home make sure that the stove is properl...

Page 26: ...ney should be inspected from time to time by a competent chimney contractor Never try to add a heat reclaimer or automatic flue damper to your gas fixnace or water heater Gas installa tion safety code...