Note:
when establishing infrared connection between the receiver and
the transmitter, the distance between them should not exceed O.5m.
When more than one system are used, only IR window of one
transmitter should be pointed to the receiver for each infrared
connection.
ECMR Receiver Setup:
Channel Selection
Press channel Selector button to select desired Channel. When
switching Channels, wait for the Channel number display to stop
blinking before using the ASC function. For best results when
operating multiple systems, set every channel to achieve the
maximum distance between channels.
Receiver Volume Control:
Turn Left for Output Level decrease, turn Right for Output Level
increase.
Mute Level Threshold Adjustment:
The Mute Level is factory set and normally needs no adjustment.
However, you may turn clockwise if interference is present.
Automatic Transmitter Setup (ASC):
Remove the access cover on the Handheld Transmitter. Point the
IR Window of the Handheld towards the IR Window on the
Receiver and press the ASC button.
Point the MBP52 Bodypack IR Window towards the Receiver IR
Window, then press the ASC buttons on both the Transmitter and
Receiver.
The Receiver transmits sync frequencies for 25 seconds each
time you press the "ASC" button.
Whenever the ASC button on the MBP52 is pressed, the
synchronizing signal will be transmitted continually for 25
seconds.