American Megatrends B.O.L.T Chest ECG User Manual Download Page 7

B.O.L.T Chest ECG 

User Manual 

 

Model No: VA 07

 

© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.

 

Page | 7

 

 

 

 

Do not expose the device to strong shocks or vibrations.  

 

The device is designed for adults and not recommended for the neonates, pediatrics 
and infants. 

 

Do not disassemble, repair, or modify the device by yourself, as this could affect the 

safety, and voids the warranty of the device if the seal is broken. 

 

The user is recommended to insert the given USB plug in the USB port of the ECG 
device during battery mode operation. 
 

 

Inserting USB Plug 

 

 

 

Removing USB Plug

 

 

 

The user can remove the USB Plug while charging the device.  

 

Adhesives  present  in  consumables  like  disposable  ECG  electrodes  are  free  from  any 
harmful  substances.  However,  if  any  allergic  reaction/irritation  is  observed,  remove 
the part immediately from human contact. Clean the area with a mild soap and water 
to remove any residual particles of adhesive.  

 

Keep the device away from infants, small children or anyone who is incapable of using 
the device in an appropriate manner. 

 

Make  sure  that  the  ECG  electrodes  positioning  place  are  clean  shaved  for  accurate 

Summary of Contents for B.O.L.T Chest ECG

Page 1: ...ONE TOUCH WIRELESS HEALTH TRACKER BODY LIFE TRACKER B O L T Chest ECG User Manual Model VA 07 Document No AMI PRD UM B VA 07 Version 1 1 Date 14 05 2018 ...

Page 2: ...ds India Private Ltd be held liable for any loss expenses or damage of any kind whatsoever whether direct indirect incidental or consequential arising from the design or use of this product or the support materials provided with the product Limited Warranty No warranties are made either expressed or implied with regard to the contents of this work its merchantability or fitness for a particular us...

Page 3: ... Manual Model No VA 07 Copyright 2018 All Rights Reserved American Megatrends India Private Ltd Page 3 Document History Version Date Comment 1 0 31 12 2015 Initial Release 1 1 14 05 2018 Updated with new images and contents ...

Page 4: ...re and Maintenance 8 4 4 Disposal 8 5 0 Contraindications 9 6 0 Product Features 9 7 0 Operating Environment 9 8 0 Prerequisites 9 9 0 Using Mobile Application 10 10 0 B O L T Chest ECG Measurement procedure 10 11 0 Charging the B O L T Chest ECG Devices 12 12 0 Troubleshooting 14 13 0 Technical Specifications 16 14 0 Explanation of Indicators Symbols 17 15 0 Certifications 19 16 0 FCC compliance ...

Page 5: ... L T Chest ECG device is a portable monitoring system which can measure monitor the electrical activity of the heart over a period of time using the ECG electrodes placed on the user s body The device monitors the ECG waveform from the Left Right chest with a reference Electrode The acquired and processed ECG data obtained from the device is transmitted to a mobile device wirelessly for further pr...

Page 6: ... met The device should be used as per the operating instructions mentioned in the user manual provided by AMI All modifications and repairs to the device are carried out by authorized AMI personnel or their agents Do not use the device when charging with a wall mount adapter as it may introduce noise in the waveform The device must comply with regulation specified in warning and cautions 4 1 Warni...

Page 7: ...ven USB plug in the USB port of the ECG device during battery mode operation Inserting USB Plug Removing USB Plug The user can remove the USB Plug while charging the device Adhesives present in consumables like disposable ECG electrodes are free from any harmful substances However if any allergic reaction irritation is observed remove the part immediately from human contact Clean the area with a m...

Page 8: ...hours during first time usage Do not disassemble repair or modify the device and the components by yourself Wipe the device using 70 Isopropyl alcohol and let air dry Do not clean with ketones or other flammable agents 4 4 Disposal Dispose of the instrument accessories and consumables according to local disposal and recycling laws This symbol is applicable for EU member countries only To avoid pot...

Page 9: ... results and health condition Comfortable accessories to use Ability to store data in B O L T Personal Health Cloud Maintain historical trend data of all vital statistics measured Multi language support Multi user login support with built in security to safeguard and protect personal health data Rechargeable Battery Extensible API to support integration with external health systems and web applica...

Page 10: ... internet unavailability which might not store the measured vital parameters in the cloud storage space on the measured parameters 10 0 B O L T Chest ECG Measurement procedure 1 Position the disposable ECG electrodes on the user s body as shown below Note Kindly replace all the 3 ECG electrodes in case of 24 hours usage While replacing do not place the electrodes in the same position Instead place...

Page 11: ...n test list 12 Choose the ECG device from the available list of vitals devices e g AMI Chest ECG 01 13 Confirm the device selection and provide default pairing password 1234 for pairing the ECG device on request for the first time pairing 14 Ensure that the Bluetooth LED stops blinking in the E C G device 15 Select Start option to perform the ECG data monitoring measurement 16 Monitoring vitals da...

Page 12: ...st ECG is operated with an inbuilt rechargeable battery which can be charged using the power adapter and USB cable as guided below It is mandatory to charge the devices for a minimum period of 2 hours before the first time usage Kindly connect the devices to the power source if low battery status is indicated in the mobile application screen Power adapter USB cable B O L T Chest ECG device Chargin...

Page 13: ...r Manual Model No VA 07 Copyright 2018 All Rights Reserved American Megatrends India Private Ltd Page 13 4 Switch ON the AC mains to charge the device 5 Check whether the power indicator turns red while charging the device ...

Page 14: ... Password is not getting updated Internet Data disconnection Enable internet connection through mobile data or Wi Fi and try again Device requests for Bluetooth pairing password Bluetooth pairing permission required Give the password as 1234 Bluetooth communication disconnected while measuring vitals and Bluetooth indicator starts blinking Bluetooth communication error Close the application Restar...

Page 15: ...gatrends India Private Ltd Page 15 authorized service center ECG device switched ON but no LED is glowing No charge for battery Connect the respective power adaptor to the ECG device and charge Then power ON if still blue LED is not glowing kindly get it repaired in authorized service center ...

Page 16: ...nnels Single Channel Input Dynamic Range 10mV Peak to Peak Bluetooth Bluetooth 4 0 EDR or Lower Bluetooth Low Energy BLE Radio Protocol Bluetooth BDR EDR BLE Operating Frequency Range 2400 MHz 2483 5 MHz Verified RF Power BT 05 45 dBm BLE 5 46 dBm Circuitry Frequency Response 0 5 Hz to 40Hz CMRR 120 dB Input impedance 5 MOhm Differential Range 5 mV A D Sampling Rate 500 samples second Resolution 2...

Page 17: ...lue o Flashing of the Bluetooth light indicates that the gadget is waiting for pairing with the mobile tab o Steady Bluetooth light indicates that the gadget is paired and ready for the measurement Green o Steady green light indicates that the gadget is operating in battery mode Red Steady red light indicates that the gadget is in the charging mode Symbol for DISPOSAL Symbol for KEEP DRY Symbol fo...

Page 18: ...ds India Private Ltd Page 18 Symbol for Follow Instructions for use Symbol for Warning Symbol for Caution Symbol for Temperature limitation Symbol for Fragile Symbol for protected against access to hazardous parts with a finger and against vertically falling water drops when tilted up to 15 degrees ...

Page 19: ...gical evaluation of medical devices Part 10 Tests for irritation and skin sensitization EN 60601 1 2012 General requirements for basic safety and essential performance EN 60601 1 2 2007 AC 2010 General requirements for safety Collateral standard Electromagnetic compatibility EN 60601 1 6 2010 Collateral standard Usability IEC 60601 1 4 1996 General requirements for safety Collateral standard Progr...

Page 20: ...the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy And if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no Guarantee that interference will not occur in a particular...

Page 21: ...y card Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit The warranty shall not apply to defects resulting from o Unauthorized modification misuse mishandling of the device o Operation of the device outside the environmental specifications of the product e g temperature electrical r...

Page 22: ... INDIA PRIVATE LTD KUMARAN NAGAR SEMMENCHERY OFF RAJIV GANDHI SALAI OMR CHENNAI TN 600119 Tel 91 44 66540922 Fax 91 44 66540901 Website www amibolt com www amiindia co in European Representative American Megatrends International GmbH Truderingerstraße Truderinger Strasse 283 81825 München Munich Deutschland Germany Tel 49 89 969995 10 Email europesales ami com ...