background image

 
MAINTENANCE INSTRUCTIONS: 

No combustible material, gasoline, or other flammable vapors or liquids should be stored near lamp. Nothing should 
obstruct the flow of combustion or ventilation air. Occasionally, the glass will need to be cleaned with household glass 
cleaner and gas mantles (if using) should be visually checked. Replace mantles if necessary. Gas lamp parts and mantles 
are available from: 
 

 

 

AMERICAN GAS LAMP WORKS LLC 

 

 

 

101 Hoeveler Street 

 

 

 

Springdale, PA 15144  

 

 

 

(Phone) 724-274-7131 or (Toll Free) 855-427-5483 

 

 

 

www.AmericanGasLamp.com

 

 

CAUTION 

 

TURN GAS SUPPLY OFF AND WAIT FOR LAMP TO COOL BEFORE PERFORMING ANY REPAIRS. 

REMOVE AND CLEAN GLASS AND REPLACE MANTLES (IF APPLICABLE) AS NECESSARY. 

 
 
INVERTED MANTLE CHANGING/LIGHTING INSTRUCTIONS: 
 

1.

 

Insert flathead screwdriver through the access hole in the lower collar of the lamp. Turn screwdriver to the right 
(to the 3:00 position) to turn off the gas.  

2.

 

Let the glass cool approximately 15-20 minutes.  

3.

 

Gently remove the glass by pushing the panel up with your fingers, then pull backward (toward you) and lower 
the panel from the bottom of the frame.  

4.

 

Carefully remove the old mantles from the ceramic burner tips by lifting the ceramic rings up, give ¼ turn, and 
pull down. Discard the old mantles and any debris lying in the bottom of the lamp.  

5.

 

Remove the new mantles from the packaging and install onto the ceramic burner tips by lifting the ceramic rings 
up and giving ¼ turn. *If using soft mantles, gently pull down to shape the mantles.* 

6.

 

With the gas still OFF, light the mantles by applying direct flame to the mantles; this is necessary to burn off the 
protective coating.  

7.

 

Once the protective coating burns off and the light goes out, insert a flathead screwdriver through the access hole 
in the lower collar of the lamp. Apply direct flame to the mantles with a lighter or a match 

 be sure not to touch 

the mantles, as they are very fragile 

 and slowly turn the screwdriver to the left (towards the 12:00 position).  

8.

 

Once lit, turn the gas on full (to the 12:00 position) and replace the glass panel. 

 

OPEN FLAME BURNER LIGHTING INSTRUCTIONS:  
 

1.

 

Insert flathead screwdriver through the access hole in the lower collar of the lamp. Turn screwdriver to the right 
(to the 3:00 position) to turn off the gas.  

2.

 

Let the glass cool approximately 15-20 minutes.  

3.

 

Gently remove the glass by pushing the panel up with your fingers, then pull backward (toward you) and lower 
the panel from the bottom of the frame. 

4.

 

Turn lamp valve ON (to the 12:00 position) with a flathead screwdriver and slowly move flame toward burner tip 
until it ignites. 

5.

 

Once lit, replace the glass panel and adjust flame to ½ - ¾ open by SLOWLY turning the lamp valve towards the 
3:00 position. Turning the valve too fast or too far can case the flame to extinguish.  

 
 
 
 
 
 
 

*For additional assistance, please contact our Customer Support Team at 724-274-7131 or 

[email protected]

.* 

Reviews: