INS_Remote Control - Gray
Page 6
P. THERMO (THERMOSTATE) MODE
This remote feature allows you to thermostatically control the fi replace
when hand held remote is set to
THERMO
mode.
Set Temperature Range: 45˚F (7˚C) to 90˚F (32˚C).
Set remote to
THERMO
mode by pressing
MODE
button. The
smaller
SET
window of numbers appears on the
LCD
screen. The
fi rst
SET
number will read 45˚F. Press
UP
button to desired set room
temperature. Within 5 seconds fi replace will operate to that Set
Temperature. The
FLAME
,
ON
and
THERMO
icons will appear on the
LCD
screen. By pressing
UP
or
DOWN
buttons a new set temperature
may be attained.
SET Temperature will only appear when THERMOSTAT MODE is
activated, but is implemented in all MODES with the exception of
MANUAL MODE.
To exit
THERMO
mode press the
MODE
button. This also shuts
fi replace
OFF
.
Q. SYSTEM OPERATION WITHOUT HANDHELD REMOTE
This system is designed to operate with the hand held remote or a
thermostat, but in the unlikely event that it is required to be operated
without the hand held remote or a thermostat, follow this simple
procedure.
Slide
REMOTE /OFF
switch on main control module to
OFF
. The
fi replace can now be lit and shut off by use of the ON/
OFF
rocker switch
located next to the module.
LEARN BUTTON
PILOT IGNITOR
CONNECTION
PILOT SENSOR
CONNECTION
REMOTE
ON/OFF SWITCH
CONTINUOUS
PILOT SWITCH
120 VAC
ADAPTER
CONNECTION
WIRE HARNESS CONNECTION
TO EXTENSION MODULE
WIRE HARNESS CONNECTION
TO VALVE STEPPER MOTOR
▲
▲
▲
▲
▲
▲
▲
▲
Switch
Remote
To OFF
Figure Q
NOTE: When operating fi replace in this capacity, the only function available is burner operation on HI.
Figure Q
NOTE: When in THERMO mode the fi replace will not turn on until room temperature falls below SET TEMPERATURE.
The fl ame height can adjust up to (6) different height levels according to amount of heat required. This range however is
dictated by the Flame Level setting (see previous page). When desired temperature is met, the fi replace will shut off until more
heat is required.
REMOTE CONTROL OPERATION
f i r e - p a r t s . c o m