american flame AF-LMF Installation And Operation Instructions Manual Download Page 3

American  Flame: AF-LMF Series Valve Kits

 

Rev. 4-26-21  Page 3

WARNING

This control system must be installed exactly as outlined in these instructions.  Read all instructions completely before attempting 

installation.  Follow instructions carefully during installation.  Any modifications of this control or any of its components will void the 

warranty and may pose a fire hazard.

These instructions must be used as a supplement to the instructions supplied with the gas log set. Follow the gas log instructions 

supplied by the manufacturer on the placement of the burner pan, log basket grate, burner media (sand or vermiculite), ember 

material and the log placement. Please follow these instructions on the connection of the inlet line to the gas valve and then to the 

burner pan assembly.

If your fireplace installation has glass doors, only operate the fireplace with glass doors in the fully open position. 

INSTALLATION: VALVE KIT WITH PRE-EXISTING LOG SET

1.   Make sure all gas flow is completely turned 

OFF

 to the gas log set. Make sure you have a certified and approved shut-off 

within 6-feet of the fireplace, or follow local code requirements.

2.   Remove all logs and basket grate and set aside.

3.   Disconnect the existing manual valve from the inlet gas supply.

4.   Remove existing manual valve and fittings on the burner pan.

5.   Locate a position on the back of the burner pan about 4-inches from the right or left side of the burner pan to mount the pilot 

assembly (Figs. 6-8).

6.   Mount pilot assembly to burner pan as shown in Figs. 6-7. Note this pilot bracket clips on the burner pan and holds the pilot 

at a 45-degree position onto the pan with no screws required. A screw can be added to secure the pilot assembly if needed. 

Carefully bend 1/4” pilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan. (This will 

hold the pilot at the 45 degree position) then connect pilot fitting to valve. 

(Use caution when bending pilot tubing not to 

kink the tubing or locate the tubing in or over the burner pan)

.   

7.   Locate the valve kit in the right or left front corner of the firebox as far forward as possible to maintain clearances    

         

      shown in Fig. 8.

8.   Bend inlet gas supply line and connect the 3/8” flare fitting to gas valve 3/8” inlet connector (Use caution not to kink the line 

when bending). 

Note:

 Use the UR3-6 adapter to convert to 1/2” fitting if applicable to installation. See Fig. 1.

9.   Bend 12” stainless flex line and connect to valve outlet then connect other end to 3/8” flare fitting on burner pan 

(Cau tion  do 

not let gas inlet line to the valve kit or gas outlet line from the valve kit be placed in or over the burner pan).

10. Turn ON gas supply and check all connections for leaks using soapy water solution.

11. Follow valve pilot lighting instructions. After pilot is lit, check pilot fittings for leaks.

12. Reinstall basket grate and logs.

13. Install Damper stop (supplied with this valve kit) on edge of damper to prevent it from fully closing. This allows damper

      to remain slightly open to allow the pilot exhaust to vent outdoors. 

14. 

CAUTION: On all PROPANE installations it is recommended that an inlet pressure regulator be used.

1.   Ensure gas is turned OFF to the existing log set before proceeding.  Make sure you have a certified and approved shut off 

within 6-feet of the fireplace, or follow local code requirements.

2.   Follow the instructions supplied with the log set to locate the burner pan. Using the fittings, orifice and gas supply line that 

came with the log set, connect the line to the inlet gas supply.

3.   Locate a position on the back of the burner pan about 4-inches from the right or left side of the burner pan. See (Figs. 6- 8)

4.   Mount pilot assembly to burner pan as shown in (Figs 6 and 7). Note this pilot bracket clips on the burner pan and holds the 

pilot at a 45-degree position onto the pan and no screws required. Note: A screw can be added to secure the pilot assembly 

if needed. Carefully bend 1/4” pilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan. 

(This will hold the pilot at the 45 degree position) then connect pilot fitting to valve. 

(Use caution when bending pilot tubing 

not to kink the tubing or locate the tubing in or over the burner pan)

5.   Locate the valve kit in the right or left front corner of the firebox as far forward as possible to maintain the clearances     

       

      shown in Fig. 8.

6.   Bend inlet gas supply line and connect the 3/8” flare fitting to gas valve 3/8” inlet connector

 (Use caution not to kink the line 

when bending).

7.   Bend 12” stainless flex line and connect to valve outlet then connect other end to 3/8” flare fitting on burner pan (

Cau tion  do 

not let gas inlet line to the valve kit or gas outlet line from the valve kit be placed in or over the burner pan).

8.   Turn ON gas supply and check all connections for leaks using soapy water solution.

9.   Follow valve pilot lighting instructions. After pilot is lit check pilot fittings for leaks.

10. Follow the instructions supplied with the log set to install ember material, basket grate and logs.

11. Install Damper stop (supplied with this valve kit) on edge of damper to prevent it from fully closing. This allows damper

      to remain slightly open to allow the pilot exhaust to vent outdoors. 

12. 

CAUTION: On all PROPANE installations it is recommended that an inlet pressure regulator be used.

INSTALLATION: VALVE KIT WITH NEW LOG SET

Summary of Contents for AF-LMF

Page 1: ...uch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier c...

Page 2: ...its See Figs 2 5 Read the description of each kit to understand how each one operates See each kit below and their contents Fig 2 AF LMF Manual ON OFF gas valve kit Fig 1 Adapter installation ON OF F...

Page 3: ...line from the valve kit be placed in or over the burner pan 10 Turn ON gas supply and check all connections for leaks using soapy water solution 11 Follow valve pilot lighting instructions After pilot...

Page 4: ...xceeded The clearance dimensions are from the burner GRATE NOT the burner pan Maintain at least 2 inches from the burner GRATE while keeping the burner pan centered to the grate Never install the valv...

Page 5: ...curity code upon initial use if batteries are replaced or a replacement transmitter is purchased from your dealer or the factory In order for the receiver to accept the transmitter security code be su...

Page 6: ...uding provisions for combustion and ventilation air must conform with local codes or in the absence of local codes to the National Fuel Gas Code ANSI Z223 latest addition This product must be on a gas...

Page 7: ...nector T102 9898 10 7 Damper Clamp 685 14 8 Receiver Shield RS 1A 9 6 volt DC Receiver For AF LMF R AF LMF RV UN3 RX 10 6 volt DC Receiver For AF LMF RVS RCAF 1035RX 11 ON OFF Transmitter For AF LMF R...

Page 8: ...ck slide switch on the receiver The switch should be in the REMOTE position See Fig 13 4 Check the 4 batteries in the receiver The total voltage of all 4 batteries should not be less than 5 3 volts 5...

Reviews: