3

DATA OUTPUT CONNECTIONS 

Data output connections are made via a terminal block located on the side of the unit. Follow the label 
on the MTM-1200B for proper orientation of data code out wires. 

Please note the terminals labeled 

‘DATA IN’ are not used on this unit.

 

 

Please note that Data Out on the MTM-1200B originated as Data in on the MRM-1200B or RRM-1200B 
before going across the fiber. 

 
MTM-1200B STATUS INDICATORS 

The MTM-1200B transmitter provides the following LED status indicators to aid in installation and 
troubleshooting: 

 
VLI 

A bi-color LED indicator is provided for the video input to the MTM-1200B. DC power and video status 
associated with this LED is summarized below. 
 

Video Presence LED 

DC Power Status 

Video Status 

Green 

On  

Proper Input Video Present 

Red 

On 

Input Video Not Detected 

Off 

Off 

Check Power Supply Input  

 
OLI 

A bi-color LED indicator monitors the power of the optical input signal that is being received at the 
MTM-1200B from the MRM-1200B or the RRM-1200B. DC power and optical input status associated 
with this LED are summarized below. 
  

Optical Level Indicator 

DC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply 