CLEARANCES
CONVENTIONAL CLEARANCES
A…SIDEWALL
9 In. (229 mm)
B…BACK WALL
3 In. (75 mm)……(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).
C…CORNER WALL
3 In (75 mm)…….(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARNACE FROM COMBUSTIBLES TO VENT PIPE).
D…VENT PIPE TO WALL 3 In (75 mm)……..(MAINTAIN 3” INCH CLEARNACE FOR ALL INSTALLATIONS)
E…FLOOR PROTECTION FRONT 6 In (150 mm)
F…FLOOR PROTECTION SIDES
6 In (150 mm)
HORIZONTAL INSTALLATION
FLOOR PROTECTION
Floor protection must be 3/8” inch
Minimum thickness non-combustible
Material or equivalent extending
Beneath
heater
and
to
the
front/side/rear
As indicated.
-
Sides of the stove to the front of the grill openings must have a 9” inch clearance.
VERTICAL INSTALLATION
CHIMNEY AND CONNECTOR: 3” LISTED PELLET VENT ONLY
NOTE: REGARDLESS OF STOVE CLEARANCE, VENT PIPE MUST ALWAYS HAVE A 3” INCH CLEARANCE.
ALCOVE CLEARANCES
MIN. ALCOVE WIDTH 41 In. (1054 mm)
MIN. ALCOVE HEIGHT 47 In. (1194 mm)
MAX. ALCOVE DEPTH 36 In. (914 mm)
MAX. ALCOVE DEPTH 36 In. (914 mm)
WARNING: THE MINIMUM CLEARNACES LISTED ABOVE ARE BASED ON 3” INCH PL LISTED
PELLET VENT PIPE. IF YOUR APPIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY
RESULT. PLEASE FOLLOW THE PIPE MANUFACTURERS INSTRUCTIONS AND LOCAL
BUILDING CODES FOR THE CLEARANCE TO COMBUSTIBLES REQUIRED FOR THE
INSTALLATION OF THE VENT PIPE BEING USED.