American Dynamics SpeedDome Optima Quick Reference Manual Download Page 5

 

RASO AND RASI SERIES SPEEDDOME OPTIMA 

8000-2692-13, REV. C 

QUICK REFERENCE GUIDE 

5 of 8

 

Supported AD Keyboards 

For systems using AD keyboards, the following 
keys are used when 

Set Preset

 or 

Call Preset

 is 

referenced:

 

 

Keyboard  

Model 

Call  

Function 

Set (Define) 

Function 

(1)

 

AD1678C/M Shot 

Set 

Shot 

(2)

 

AD2078 Call 

Set 

AD2078A Call Set 

AD2079 Shot 

Shot 

AD2088 Shot 

Shot 

ADTTE Shot 

Shot 

ADTT Call 

Set 

 

NOTES: 

(1)  Keyboard must be in programming mode to 

use the set functions. See the keyboard 
operation manual for information. 

(2)  Recessed pushbutton switch.  

Supported Dome 

Commands 

Some dome commands are supported through 
special keystroke combinations. This section 
summarizes those commands for specific 
controllers. 

AD2083-02A Code Converter 

See 

Supported AD Keyboards

 for button names 

used on specific keyboards. 

Verified with AD168 (v. 3.01) and AD2083-02A (v. 11Y9). 

Dome Function 

Keyboard Command 

Define Preset 1 - 16  

1 - 16 Set Shot 

Recall Preset 1 - 16  

1 - 16 Call Shot 

Define Pattern #1  

17 Set Shot 

Define Pattern #2  

18 Set Shot 

Define Pattern #3  

19 Set Shot 

End Pattern Definition  

33 Set Shot 

Accept (save) New Pattern  

34 Set Shot 

Go to Pattern #1  

17 Call Shot 

Go to Pattern #2  

18 Call Shot 

Dome Function 

Keyboard Command 

Go to Pattern #3 

19 Call Shot 

Run Pattern #1  

21 Call Shot 

Run Pattern #2  

22 Call Shot 

Run Pattern #3  

23 Call Shot 

Review Temporary Pattern  

24 Call Shot 

Auto Repeat Pattern #1 

25 Call Shot 

Auto Repeat Pattern #2  

26 Call Shot 

Auto Repeat Pattern #3  

27 Call Shot 

Flip (rotate dome 180°)  

40 Call Shot 

Clear Pattern #1  

41 Set Shot 

Clear Pattern #2  

42 Set Shot 

Clear Pattern #3  

43 Set Shot 

Reset Dome 

66 Set Shot 

Enter V-Phase Adjust 
Mode 

67 Set Shot 

followed by 

multiple

 Iris Open 

or

  

Iris Close 

Exit V-Phase Adjust Mode  

68 Set Shot 

Return to Auto-Iris/Auto 
Focus  

69 Call Shot 

Reset Iris  

69 Set Shot 

 

In addition, the following commands 

are not

 

supported. 

• 

Set Switch 1 Normal Closed (51 Set Shot) 

• 

Set Switch 1 Normal Open (52 Set Shot) 

• 

Set Switch 2 Normal Closed (53 Set Shot) 

• 

Set Switch 2 Normal Open (54 Set Shot) 

• 

Set Switch 3 Normal Closed (61 Set Shot) 

• 

Set Switch 3 Normal Open (62 Set Shot) 

• 

Set Switch 4 Normal Closed (63 Set Shot) 

• 

Set Switch 4 Normal Open (64 Set Shot) 

Summary of Contents for SpeedDome Optima

Page 1: ... 3 Clearing Patterns 3 DirectSet Menu Commands 3 Supported Controllers and Matrix Switching Systems 4 Supported Dome Commands 5 Declarations 8 Sensormatic 2004 About this Guide This Quick Reference Guide explains the functions supported by the SpeedDome Optima programmable dome camera It is intended to supplement information included in the operator s manual for your video controller or matrix swi...

Page 2: ...ported may differ for your controller Table 1 Protocols and supported features Feature SensorNet RS 422 Manchester Maximum Presets 96 a 96 a 64 Maximum Patterns 3 3 3 Resume Auto Focus Auto Iris b Yes Yes Yes Dome Reset Yes Yes Yes V Phase adjustment Yes Yes Yes Auxiliary output control Yes Yes Yes a The actual number of available presets may differ based on the controller used b Pressing the Iris...

Page 3: ...attern for the selected pattern For more information about programming patterns refer to your controller operator s manual Note If Pattern 3 is cleared this removes the home position programming The dome will not automatically return to the specified preset or pattern after 10 minutes of dome inactivity Pattern Programming Summary Commands Result Start Pattern programming followed by stop Pattern ...

Page 4: ... 6 64 SensorNet 64 Manchester 16 RS 422 64 Manchester 16 RS 422 Maximum Available Patterns 4 3 3 3 3 3 3 3 3 3 3 DirectSet menu 5 Yes 7 No No No Yes 8 Yes 8 No No No No NOTES 1 For the list of compatible keyboards see Supported AD Keyboards on page 5 2 RS 422 is supported with the appropriate code converter 3 Preset information is stored at the host not the dome 4 Patterns are limited by time and ...

Page 5: ...et Shot Define Pattern 2 18 Set Shot Define Pattern 3 19 Set Shot End Pattern Definition 33 Set Shot Accept save New Pattern 34 Set Shot Go to Pattern 1 17 Call Shot Go to Pattern 2 18 Call Shot Dome Function Keyboard Command Go to Pattern 3 19 Call Shot Run Pattern 1 21 Call Shot Run Pattern 2 22 Call Shot Run Pattern 3 23 Call Shot Review Temporary Pattern 24 Call Shot Auto Repeat Pattern 1 25 C...

Page 6: ... Definition 68 Shot Save New Pattern 69 Shot Clear Pattern 1 62 Shot Clear Pattern 2 63 Shot Clear Pattern 3 64 Shot Enter V phase Adjustment 67 Shot followed by iris open close Exit V phase Adjustment 67 Shot MegaPower 48 Matrix Switcher Controller System See Supported AD Keyboards for button names used on specific keyboards Dome Function Keyboard Command Define Pattern 1 121 F2 Define Pattern 2 ...

Page 7: ...0 F1 Enter Vertical Phase Adjust Mode 38 F2 Exit Vertical Phase Adjust Mode 39 F2 In addition the following commands are not supported Set Auxiliary 4 OFF 70 F1 Set Auxiliary 4 ON 71 F1 Manchester Commands These commands are supported by systems using the Manchester protocol See Supported AD Keyboards for button names used on specific keyboards Verified with AD2050 AD2091 and AD168 with CCM v 3 01...

Page 8: ...t is your point of contact if you have a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net NOTICE The information in this manual was current when published The manufacturer reserves the right to revise and improve its ...

Reviews: