Dome Features 

The SpeedDome Optima programmable dome 
camera provides the following features: 

• 

22X optical zoom/11X digital zoom  
(242X maximum total zoom). 

• 

470 lines horizontal resolution 

• 

Zoom Adjusted Programming (ZAP) 

• 

Auto Focus / Auto Iris 

• 

Auto White Balance 

• 

Automatic Gain Control (AGC) 

• 

Line-lock 

• 

Up to 96 presets (system dependent) 

• 

Three patterns 

• 

Programmable home position  

• 

Apple Peel 

• 

Dome Flip (rotate 180

°

• 

One alarm input 

• 

One auxiliary output 

• 

Power-on functional tests 

• 

LED diagnostics 

• 

DirectSet menu commands for specific dome 
functions 

In addition, the dome may be used with the 
Manchester, RS-422, RS-485, or SensorNet 
protocols. 

Although SpeedDome Optima does not provide 
on-screen programming via the dome firmware, the 
connected controller may be used to configure 
many settings. These settings include: 

• 

Programming presets and patterns 

• 

Vertical phase adjustment (V-phase) 

• 

Auxiliary output control 

The following table provides additional information 
about the supported controller functions with the 
protocol used. The actual features supported may 
differ for your controller. 

Table 1: Protocols and supported features 

Feature SensorNet RS-422  Manchester 

Maximum 

Presets 

96 (a) 

96 (a) 

64 

Maximum 

Patterns 

3 3 

Resume 

Auto Focus 

/ Auto Iris 

(b)

 

Yes Yes 

Yes 

Dome 
Reset 

Yes Yes 

Yes 

V-Phase 

adjustment 

Yes Yes 

Yes 

Auxiliary 

output 

control 

Yes Yes 

Yes 

(a)  The actual number of available presets may 

differ based on the controller used. 

(b)  Pressing the Iris Open and Iris Close buttons 

simultaneously returns to auto focus and auto 
iris mode. 

For specific information about the features 
supported, see the operator's manual for your 
controller.  

Controlling the Zoom 

Setting 

Zoom stop settings define how the zoom function is 
partitioned. Depending on the current zoom level, 
the camera will either stop at the first zoom stop 
setting or continue to the maximum zoom setting. 
For SpeedDome Optima, the first zoom stop 
setting is 22X (maximum optical zoom). The 
maximum zoom is 242X (maximum digital zoom). 

To switch between optical and digital zoom levels, 
press the 

Zoom In 

(Zoom Tele) button until the first 

zoom stop is reached. Release the button for at 
least one second and press 

Zoom In

 again to 

continue into the digital zoom range. Zooming 
stops when the maximum zoom is reached.  

Refer to your controller instructions for information 
about the location of the zoom control buttons. 

Summary of Contents for SpeedDome Optima

Page 1: ... 3 Clearing Patterns 3 DirectSet Menu Commands 3 Supported Controllers and Matrix Switching Systems 4 Supported Dome Commands 5 Declarations 8 Sensormatic 2004 About this Guide This Quick Reference Guide explains the functions supported by the SpeedDome Optima programmable dome camera It is intended to supplement information included in the operator s manual for your video controller or matrix swi...

Page 2: ...ported may differ for your controller Table 1 Protocols and supported features Feature SensorNet RS 422 Manchester Maximum Presets 96 a 96 a 64 Maximum Patterns 3 3 3 Resume Auto Focus Auto Iris b Yes Yes Yes Dome Reset Yes Yes Yes V Phase adjustment Yes Yes Yes Auxiliary output control Yes Yes Yes a The actual number of available presets may differ based on the controller used b Pressing the Iris...

Page 3: ...attern for the selected pattern For more information about programming patterns refer to your controller operator s manual Note If Pattern 3 is cleared this removes the home position programming The dome will not automatically return to the specified preset or pattern after 10 minutes of dome inactivity Pattern Programming Summary Commands Result Start Pattern programming followed by stop Pattern ...

Page 4: ... 6 64 SensorNet 64 Manchester 16 RS 422 64 Manchester 16 RS 422 Maximum Available Patterns 4 3 3 3 3 3 3 3 3 3 3 DirectSet menu 5 Yes 7 No No No Yes 8 Yes 8 No No No No NOTES 1 For the list of compatible keyboards see Supported AD Keyboards on page 5 2 RS 422 is supported with the appropriate code converter 3 Preset information is stored at the host not the dome 4 Patterns are limited by time and ...

Page 5: ...et Shot Define Pattern 2 18 Set Shot Define Pattern 3 19 Set Shot End Pattern Definition 33 Set Shot Accept save New Pattern 34 Set Shot Go to Pattern 1 17 Call Shot Go to Pattern 2 18 Call Shot Dome Function Keyboard Command Go to Pattern 3 19 Call Shot Run Pattern 1 21 Call Shot Run Pattern 2 22 Call Shot Run Pattern 3 23 Call Shot Review Temporary Pattern 24 Call Shot Auto Repeat Pattern 1 25 C...

Page 6: ... Definition 68 Shot Save New Pattern 69 Shot Clear Pattern 1 62 Shot Clear Pattern 2 63 Shot Clear Pattern 3 64 Shot Enter V phase Adjustment 67 Shot followed by iris open close Exit V phase Adjustment 67 Shot MegaPower 48 Matrix Switcher Controller System See Supported AD Keyboards for button names used on specific keyboards Dome Function Keyboard Command Define Pattern 1 121 F2 Define Pattern 2 ...

Page 7: ...0 F1 Enter Vertical Phase Adjust Mode 38 F2 Exit Vertical Phase Adjust Mode 39 F2 In addition the following commands are not supported Set Auxiliary 4 OFF 70 F1 Set Auxiliary 4 ON 71 F1 Manchester Commands These commands are supported by systems using the Manchester protocol See Supported AD Keyboards for button names used on specific keyboards Verified with AD2050 AD2091 and AD168 with CCM v 3 01...

Page 8: ...t is your point of contact if you have a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net NOTICE The information in this manual was current when published The manufacturer reserves the right to revise and improve its ...

Reviews: