Troubleshooting 

This section covers what to do when: 

  Dome does not respond to commands 

  Fans do not turn 

  Picture is grainy or discolored 

 Poor 

video 

  Ice forms on bubble. 

Dome Does Not Respond to Commands 

Follow steps until the problem is corrected. See 
page 5 to order parts. 

1.  Detach the camera dome from the base and 

check the address switches. Are they set 
correctly? 
- YES: 

Continue. 

-  NO: Set the correct address and reconnect 

the dome. 

2.  Verify power is reaching the housing. Press and 

hold switch SW2 on the environmental PC 
board and observe the green (ac power) LED. 
Does the LED glow steadily? 
-  YES: Reattach the dome and continue. 
-  NO: Check power at the J-box and ac cable 

connections at connector P7 on the other 
side of the environmental PC board. If OK, 
replace the PC board. 

Connector P7 pin outs 

Pin Color  Description 
1 N/A  24Vac 
2 N/A  EMI 

Ground 

3 N/A  24Vac 

CAUTION:

 Use a 2.5mm (0.1in) slotted 

screwdriver. Using a blade too wide can 
damage connectors. 

CAUTION:

 Screws on the ac connector are 

delicate. DO NOT over tighten them! 

3.  Verify data is reaching the housing. 

SENSORNET or RS-422: Press and hold switch 
SW2 on the environmental PC board and 
observe the yellow (comm.) LED. The LED 
should blink (SensorNet) or glow steadily 
(RS-422). 
To verify RS-422 connections at connector P1, 
press and hold data test switch SW1 on 
environmental PC board. Check the nearby red 
and green LEDs; they indicate the following: 

Constant green, 
Blinking red 

RS-422 line is correctly 
wired. 

Constant green, 
No red 

RS-422 “Data In –” is 
shorted to circuit ground. 

Constant red, 
Blinking green 

“Data In + /–” wires are 
reversed. 

Blinking red, 
Green off 

“Data In +” is shorted to 
circuit ground. 

Both LEDs off 

“Data In +/–” wires are 
shorted or open. 

P1 pin outs: 

Manchester data connections (Ultra IV only) 

Pin Color  Designation 
1-4 — 

Not 

used. 

5 Black Manchester 

(+) 

6 White Manchester 

(–) 

 

RS-422 Data connections 

Pin Color  Designation 

Orange 

RS-422 Data In High (+) 

Green 

RS-422 Data In Low (–) 

Yellow 

RS-422 Data Out High (+) 

Brown 

RS-422 Data Out Low (–) 

5-6 — 

Not 

used. 

Summary of Contents for RHODUL-03E

Page 1: ... housing to mounting structure Attach cable connectors 0100 2468 02 Standard Housing 0101 0061 02 Vandal Resistant Housing Blue alarm connector used with 02 housings only Pin 1 24Vac Pin 2 EMI Ground Pin 3 24Vac Pin 1 White Blue Alarm 2 3 5mA sink Pin 2 White Brown Pin 3 White Purple Pin 4 White Red Alarm Return Alarm 3 3 5mA sink Alarm 4 3 5mA sink Pin 1 Blue Relay NC Pin 2 Purple Relay armature ...

Page 2: ... and affix bag to top of mounting base adhesive side down 8200 0184 10 Rev C Page 2 of 12 IMPORTANT Power the dome heater fans turn on and check it performs its homing routine During this routine the camera lens moves up into the dome housing down to the floor pans slowly and moves up to its home position The controller can then be used to call up and control the dome If OK continue If not see Tro...

Page 3: ... been pulled to the installation site To install the outdoor mounting structure see documents shipped with the structure About the Product The outdoor housing has a sunshield cover and bubble that protect the SpeedDome Ultra dome camera Tamperproof screws affix the bubble to the housing The housing is temperature controlled and weatherproof A built in thermostat and heater prevent ice from forming...

Page 4: ...if inher ently limited with 8 amps maximum output current and a maximum of 100VA available or if not inherently limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through American Dynamics or through another source where the provider can furnish the verification This is required to assure electrical safety...

Page 5: ...s the gasket seal between the bubble and the housing Plugged drain holes in the bubble trim ring Cracked bubble Tamperproof screws that are missing or improperly tightened compromise the gasket seal between the bubble and the housing Ensure lanyard is not caught between a flange and trim ring gasket and b trim ring and sunshield Parts List for Authorized Users The parts listed below and shown in t...

Page 6: ...munication protocols and cable networks see Communication Protocols and Cable Networks 8000 2573 19 Data cable requirements SensorNet RS 422 Manchester Cable type 1 unshielded twisted pair 2 shielded twisted pair 1 shielded twisted pair Wire gauge 22 AWG 22 AWG 18 AWG Connection Non polarized Polarized Polarized Max devices on line 32 10 3 Power data and video cables can be ordered separately or w...

Page 7: ...fer to controller matrix switcher instructions for information about controlling outputs auxiliaries Command Priority If both commands to control the heaters are issued in sequence the first command runs to completion 3 hours 23 minutes then the second command runs For example the command to run the heaters on continuous high mode is issued Output Auxiliary 4 On Five minutes later the command to r...

Page 8: ...al housing to discharge it before touching the board 1 As shown above detach the circuit board from the housing by A Pushing fingers molded into the base away from the board while B Pulling on the dust cover protecting the board s spring finger connector Note Keep the dust cover in place for the next two steps 2 On the top side of the circuit board place jumper E1 across pins 1 2 for unterminated ...

Page 9: ...N A 24Vac CAUTION Use a 2 5mm 0 1in slotted screwdriver Using a blade too wide can damage connectors CAUTION Screws on the ac connector are delicate DO NOT over tighten them 3 Verify data is reaching the housing SENSORNET or RS 422 Press and hold switch SW2 on the environmental PC board and observe the yellow comm LED The LED should blink SensorNet or glow steadily RS 422 To verify RS 422 connecti...

Page 10: ...ch as a picture on the video monitor or dome movement 2 Detach the dome camera to access the environmental PC board Note Power to fans comes from the dome Fans will not function with the dome removed CAUTION Touch the metal housing before handling the environmental PC board 3 Verify power is reaching the housing Press and hold switch SW2 and observe the green ac power LED it should glow steadily I...

Page 11: ...ing the two screws NO Plug the connector in reinstall the environmental PC board and reattach the dome If the fans still do not work replace the fan heater assembly Specifications Electrical combined dome and housing Input Voltage 24 to 30Vac 50 60 Hz UL Listed Class 2 Certified Limited Power Source Design Tolerance 20 to 36Vac 50 60 Hz Power Consumption 80W max Power On In Rush current 3A Surge P...

Page 12: ...mpowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any par...

Reviews: