American Dynamics RCSN422 Installation Manual Download Page 7

 

SENSORNET TO RS-422 CODE CONVERTER 

8000-2593-01, REV. C 

INSTALLATION GUIDE 

7 of 7

 

Addendum F: 

Flashing Firmware on the RCSN422 Using an ADCASNET Module 

 

 

Procedure 

1.  Download and install the ADCASNET utility from 

http://www.americandynamics.net

. Click on 

Support/Software Downloads/USB Control Module/USB Control Module Utilities/ADUtils_1_00.zip. 

2.  Download RCSN422 hex file from the web site and copy it to c:\program files\AD_Utilities (

Note:

 This file 

must be F2814-0102 or higher). 

3.  Set the code converter to address 32. 

4.  Launch the ADCASNET utility and click “Load Utility”. 

5.  Click the “Scan Network” icon; the load utility will look for the code converter on the right-hand screen. 

6.  Once it detects the code converter, the firmware version is displayed. For example: 2814-XXXX. 

7.  Click on the displayed version and then click “Load Snet Device”. A progress bar appears. 

8.  When complete, close the ADCASNET utility and reboot the code converter. 

9.  Rescan the code converter and verify firmware was updated. 

Summary of Contents for RCSN422

Page 1: ...tallation The converter can be placed on a tabletop or installed in a rack under a shelf or on a wall Parts Supplied Install Kit 0351 1635 01 which includes Mounting Bracket 2 Screw PHP M3x8 4 Connect...

Page 2: ...First blink indicates a successful ROM check second blink indicates a successful RAM check LED illuminates continuously when either check fails stopping the test Remains illuminated during program loa...

Page 3: ...EU ist es f r den Betrieb durch eine begrenzte Stromquelle vorgesehen Eine begrenzte Stromquelle ist eine zertifizierte SELV Quelle Schutzkleinspannung bei inh renter Begrenzung mit einem maximalen A...

Page 4: ...instructions For just the ping test refer to MegaPower LT operation instructions MP LTHB 1 Note If a controller requests device information from a camera having the same address as the converter the c...

Page 5: ...L 860 AP J Box To MiniDome To Unicard SpeedDome To Optima To Optima LT To SpeedDome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 R...

Page 6: ...Dome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 RX Pin 2 TX Pin 2 RX Pin 6 RX Pin 2 RX Pin 2 RX Pin 7 RX Pin 2 RX Pin 3 AC Pin 3...

Page 7: ...y it to c program files AD_Utilities Note This file must be F2814 0102 or higher 3 Set the code converter to address 32 4 Launch the ADCASNET utility and click Load Utility 5 Click the Scan Network ic...