SPEEDDOME OPTIMA HOUSING
8000-2692-01, REV. E
CONTINUATION OF INSTALLATION GUIDE
7 of 18
Preventing Condensation in
Outdoor Domes
Damage, missing parts, or procedures
that most often allow water to enter
the housing are as follows (refer to
figures opposite):
Mounts that allow water to enter the air path. If
an older horizontal mount is used, replace it
with a new model or ensure there is ample
slope away from the camera dome and a foam
plug is present
Missing foam plug from entry into the pipe of
the mounting structure
Missing O-ring on cover, or missing sleeve or
seal on end cap assembly
Missing Teflon tape around any housing pipe
threads
RTV or similar sealant covering an air path
Loose nuts (4) at the top of the housing
Heater fans not turning
Bent flange on metal housing that
compromises the gasket seal between the
bubble and the housing
Plugged drain holes in the bubble trim ring
Cracked
bubble
Tamperproof screws that are missing or
improperly tightened compromise the gasket
seal between the bubble and the housing
Ensure lanyard is not caught between: a)
flange and trim ring gasket, and b) trim ring
and sunshield.
Connector Pin Assignments
GREEN CONNECTOR (POWER)
Pin Color Description
1 Black 24Vac
2 Red Common
3 White 24Vac
BLACK CONNECTOR (DATA)
Manchester
Pin Color Designation
1-4
Not
used.
5 White Manchester
(+)
6 Black Manchester
(–)
RS-422 / SensorNet
Pin Color Designation
1
Orange
RS-422 Data In High (+)
2
Green
RS-422 Data In Low (–)
3
Yellow
RS-422 Data Out High (+)
4
Brown
RS-422 Data Out Low (–)
5 Orange
SensorNet
(unshielded)
6
Yellow
SensorNet (unshielded)
*Color based on composite cable.
GRAY CONNECTOR (RELAY OUTPUTS)
Pin Color Description
1 N/A Normally
Closed
2 N/A Common
3
N/A
Normally Open (3.5mA sink)
4 N/A Alarm
Return
5
N/A
Alarm input (3.5mA sink)