SpeedDome Optima Indoor Installation Guide

RASI Series

2

Before performing these steps, ensure power is off and 
read additional information attached for important 
details and warnings!

Using the template 
supplied, cut a hole in 
the ceiling.

Adjust all four “swing 
out” mounting clips for 
the ceiling thickness..

8000-2692-01, Rev. E

Page 1 of 18

3

4

Attach cable connectors. 
Ensure power is off.

Use screwdriver 
supplied to tighten 
connector screws. DO 
NOT over tighten the 
connectors!

Place cover 
on housing.

Secure cable to 
housing using the 
cable tie supplied.

If running cables through 
conduit (not shown), remove 
appropriate knockout (1/2in 
Or 3/4in), and connect 
conduit to the cover.
If running cables direct 
(shown), attach the clamp 
and nut assembly supplied to 
one of the 1/2in knockouts in 
the side of the cover.

Video 

Power 

(Green) 

Data 

(Black) 

O

n

 C

a

bl

RS422 

SensorNet 

Manchester 

NC

 

NO 

*A

*A

R+

 

R–

 

T+

 

T–

 

+  – 

~ (

A

C

~ (

A

C

GND

 

BL

K

 

RE

D

 

WH

T

 

OR

G

 

GRN

 

YE

BR

N

 

OR

G

 

YEL

 

Input 

Output 

BL

K

 

WH

T

 

Alarm 

(Grey) 

Cable 
hookup

A

D

B

C

Set the dome address and 
terminate the dome, if 
necessary.

The camera/motor assembly is shipped 
“terminated” (switch to left) for when it is installed 
at the end of a data cable. Should the cable 
continue to another dome, move the slide 
switch to the right to “unterminate”.

A

B

Terminate 
Switch

Address Switches

SW3 SW2 SW1 

x100 x10  x1 

The address range is from 001 to 255, 
except for Manchester, which is 01 to 64.

Set switches. Example: For address 107, 

set SW3 to 1, SW2 to • , and SW1 to 7.

 

Summary of Contents for RASI series

Page 1: ...nd connect conduit to the cover If running cables direct shown attach the clamp and nut assembly supplied to one of the 1 2in knockoutsin the side of the cover Video Power Green Data Black On Cable 1 RS422 SensorNet Manchester NC C NO AR AI R R T T 1 1 AC AC GND BLK RED WHT ORG GRN YEL BRN ORG YEL Input Output BLK WHT Alarm Grey Cable hookup A D B C S et the dome addressand terminate the dome if n...

Page 2: ...hen attach the S hook to the housing Close the ends of the S hook Attach the end of the chain to itself using another S hook Close the ends of the S hook Run the chain up into the ceiling and wrap it around a structural member above the housing Keep the chain taught as possible Do not secure the housing to a fire control system A A A B B B C C C Green red and yellow LEDs will light in various patt...

Page 3: ...the Roof Mount RHOSW Short Wall Mount or RHOLW Long Wall Mount T hread cables through end cap assembly and attach housing to mounting structure Attach cable connectors in kit 0351 1686 01 P in 1 24V ac P in 2 Common P in 3 24V ac P in 1 NC P in 2 Common P in 3 NO 3 5mA sink P in 4 Alarm return P in 5 Alarm input 3 5mA sink P in 1 4 Not used P in 5 White P in 6 Black P in 1 4 Not used P in 5 Orange...

Page 4: ...hes Example For address 107 set S W3 to 1 S W2 to and S W1 to 7 Align the three arms of the chassis over the tabs inside the sunshield of the housing Heater assembly Arm spacing is not symmetrical Dome goes into housing only one way P ush the assembly up into the housing until it snaps in place S ecure using captive screws in the arms B T Ensure all four tamperproof screws are tight Once the bubbl...

Page 5: ...the housing is attached is in place and that data and power cables have been pulled to the installation site To install the outdoor mounting structure see documents shipped with the structure Special Product Features Indoor Outdoor Housing The dome camera has one alarm input and one SPDT relay Surge protection is provided on all external lines including video Outdoor Housing Only The outdoor housi...

Page 6: ...of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through Sensormatic or through another source where the provider can furnish the verification This is required to assure electrical safety in the product Cautions To protect the bubble assembly leave it in its box until you are ready to install it Do not run data power cables adjacent to or...

Page 7: ...ng that compromises the gasket seal between the bubble and the housing Plugged drain holes in the bubble trim ring Cracked bubble Tamperproof screws that are missing or improperly tightened compromise the gasket seal between the bubble and the housing Ensure lanyard is not caught between a flange and trim ring gasket and b trim ring and sunshield Connector Pin Assignments GREEN CONNECTOR POWER Pin...

Page 8: ...ble Plenum ceilings Cable must be rated for plenum and routed through electrical conduit Use the cable connection cover for conduit termination and cable connections to the dome Knockouts in the cover accept and conduit WARNING Do not run data and power cables adjacent to or in the same conduit as line voltage mains power Power cables Make power cable lengths as short as possible to minimize the a...

Page 9: ...able distance between the outdoor SpeedDome Optima and the 1 position and 6 position see Note below junction boxes for several worst case low line voltages The distances are shown for 18 16 and 14 AWG ac power cabling 14 AWG is larger than 18 AWG and has lower resistance thus the 14 AWG has a larger current capacity and supports a longer cable distance Worst Case Line Voltages 18 AWG 16 AWG 14 AWG...

Page 10: ...n red and yellow LEDs through the housing LED Indication Cause Yellow blinks Wiring OK Red flickers Green blinks RS 422 wired backwards Red blinks Green flickers A wire is not connected Fix wiring 2 Reset the dome to the desired address No video 1 Check the video cable and its connection to the dome If not OK fix or replace cable 2 Check the iris setting Open iris or set to auto iris 3 If the prob...

Page 11: ...18 Illustrated Parts List Not all of the parts which are shown for clarity are orderable Parts are subject to change based on design improvements and availability Indoor Housing Hard Ceiling Housing Assy 0400 1246 01 1 Housing Assembly 0400 1246 01 2 Cable Assy Pigtail 0650 2206 01 1 2 ...

Page 12: ...1 4 Sun Shield 0500 7954 01 5 Top Cover 0500 8001 01 6 Mounting Support 0500 9288 01 7 Nut Locking M6 SS 4 5826 0500 020 8 Washer FL STD M6 4 5840 0500 020 9 Gasket 0500 9375 01 10 Lock Nut 1 1 2 6010 0100 01 11 Screw M6x40 HHD 5801 4134 520 Indoor Outdoor Pigtail Only 0400 1221 01 12 Bracket Mounting 0500 9185 01 13 Cable Assy Pigtail 0650 2206 01 10 5 4 7 8 6 9 3 12 11 13 ...

Page 13: ...SPEEDDOME OPTIMA HOUSING 8000 2692 01 REV E CONTINUATION OF INSTALLATION GUIDE 13 of 18 Camera Motor Assembly 18 20 19 22 21 17 14 15 16 Tilt Assy 0400 1207 01 02 Base Assy 0400 1203 01 ...

Page 14: ... 14 Bearing Pan 2510 0040 01 15 Pan Motor Assy 0400 1240 01 16 PCB Dome System 0301 1516 01 Tilt Assy 0400 1207 01 NTSC 02 PAL 17 Base Tilt 0500 9110 01 18 Spacer Tilt 2 0505 0085 01 19 Tilt Upright 2 0500 9168 01 20 Timing Belt 2500 0041 01 21 Tilt Motor with Pulley 3501 0024 01 22 PCB Tilt Sensor 0301 1524 01 ...

Page 15: ...operation 500 000 position changes Relays are rated at 2X 105 operations Color Camera Type Interline Transfer CCD array Scanning system 2 1 interlace Horizontal resolution 470 lines at center Video out 1 0 Vp p 75 ohms composite Signal Noise 50dB typical Minimum illumination 1 0 lux 20 IRE Gain control Automatic AGC White balance Through the Lens TTL Automatic Tracing White Balance ATW NTSC versio...

Page 16: ...lses discharge current 5kA Isolation transformer coupled 2000Vrms PTC resettable fuse protects transformer TVS rated at 5 6V 40A 0 1 Joules 8 20µs impulse EIA 422 comm Gas discharge tube impulse rated at 8 20µs Impulse Discharge Current 10kA Ten 8 20 µs Impulses Discharge Current 5kA 33 ohm series resistors TVS rated at 5 6V 40A 0 1 Joules 8 20µs impulse Alarm input Gas discharge tube impulse rate...

Page 17: ...ay Output Provides contact closure output from dome output Contact type Form 1 C NO NC and common connections Isolation 1kV Contact material Gold clad silver alloy Contact rating 30Vac or Vdc 1A Connector Plug in Euro style terminal block 3 81mm Mechanical Housing diameter 190mm 7 5in Bubble diameter 178mm 7 0in Housing height above ceiling 210mm 8 26in Bubble depth below ceiling 94mm 3 7in Pipe c...

Page 18: ... very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose NOTICE ...

Reviews: