ADTT16E TOUCH TRACKER CONTROLLER WITH INTELLEX
8000-2637-02, REV. C
INSTALLATION INSTRUCTIONS
6 of 6
Providing System
Information
1. Press
Menu
.
2. Using the Tracker Ball, scroll down to
System
Info
.
3. Press the left zoom/focus button (line 1) or right
zoom/focus button (line 2) to select the
System
Info
menu option. The LCD screen displays
the following message:
Primary Unit
4. Press
Next
to step through the following
messages:
ROM Checksum
0A7B
Tilt FSR Calibration Values
Min 11 22 33 44
Max 55 66 77 88
Pan FSR Calibration Values
Left
Right
Up Down
Product Code
F 7000-0020-0102
Indicates Flash PROM
Product Code
E 0701-0010-0105
Indicates EEPROM
5. Press
Menu
to exit.
Performing SensorNet Ping
Test
1. Use the number buttons to select a dome to
reset, then press
Cam
.
2. Press
Menu
.
3. Using the Tracker Ball, scroll down to
Ping Dome/TTR
.
4. Press the left zoom/focus button (line 1) or right
zoom focus button to select the
Ping Dome/TTR
menu option and test the
selected dome.
5. Press
Next
to perform the network test on the
Primary controller unit.
6. Press
Menu
to exit.
Off-line domes or fixed cameras will generate a
warning beep and disallow use of the
SensorNet network test.