background image

ADTT16E TOUCH TRACKER CONTROLLER WITH INTELLEX 

8000-2637-02, REV. C 

INSTALLATION INSTRUCTIONS 

6 of 6 

 

 

Providing System 
Information 

1. Press 

Menu

2.  Using the Tracker Ball, scroll down to 

System 

Info

3.  Press the left zoom/focus button (line 1) or right 

zoom/focus button (line 2) to select the 

System 

Info

 menu option. The LCD screen displays 

the following message: 

 

Primary Unit

 

4. Press 

Next

 to step through the following 

messages: 

 

ROM Checksum
 0A7B

 

 

Tilt FSR Calibration Values

Min   11  22  33  44

Max   55  66  77  88

Pan FSR Calibration Values

Left

Right

Up Down

 

 

Product Code

F  7000-0020-0102

Indicates Flash PROM

 

 

Product Code
E  0701-0010-0105

Indicates EEPROM

 

5. Press 

Menu

 to exit. 

 

Performing SensorNet Ping 
Test 

1.  Use the number buttons to select a dome to 

reset, then press 

Cam

2. Press 

Menu

3.  Using the Tracker Ball, scroll down to 

Ping Dome/TTR

4.  Press the left zoom/focus button (line 1) or right 

zoom focus button to select the 

Ping Dome/TTR

 menu option and test the 

selected dome. 

5. Press 

Next

 to perform the network test on the 

Primary controller unit. 

6. Press 

Menu

 to exit. 

 

 

 

Off-line domes or fixed cameras will generate a 
warning beep and disallow use of the 
SensorNet network test. 

 
 

Summary of Contents for ADTT16E Touch Tracker

Page 1: ...ion 3 Intellex 2 0 Connection 4 Calibrating the Tracker Ball 5 Configuring Devices 5 Resetting a Dome 5 Toggling between Zoom and Focus 5 Adjusting V Phase 5 Providing System Information 6 Performing SensorNet Ping Test 6 2005 Sensormatic Electronics Corp About this Guide This installation guide explains the wiring of the ADTT16E Touch Tracker Controller with the Intellex Digital Video Management ...

Page 2: ...all or other surface within 3m 10 of the ADTT16E Touch Tracker 3 Connect the power transformer and SensorNet cable to J3 on the EIM 4 Connect the DB9M DB9F Serial Cable PN 6003 0017 05 to the DB9 connectors on the EIM and Intellex back panel Refer to the illustrations on pages 3 or 4 for additional information 5 Connect the data cable from J1 on the main ADTT16E Touch Tracker EIM to the Remote por...

Page 3: ...und White 5 24 Vac B PIN FUNCTION 5 4 3 2 1 J Box 1 EIM 1 DB9 M RJ45 RJ45 P1 P2 P3 P4 P5 P6 P8 UniCard P3 UniCard P3 ASSY 0301 0340 01 REV 3 2 1 TERMINATED DB9 F P1 P2 P3 P4 P5 P6 P8 3 5 4 J Box 2 Main Touch Tracker Intellex 1 x with DB9 Connector 24 Vac A 24 Vac B Ground Serial Cable PN 6003 0017 05 RPNR00 Terminate E1 on EIM 1 E1 The ma ximum combined SensorNet cable length is 1000 m 3000 5 4 3 ...

Page 4: ...PNR00 Terminate E1 on EIM 1 E1 The maximum combined SensorNet cable length is 1000 m 3000 5 4 3 2 1 COLOR Orange 1 Host A Yellow 2 Host B Orange Auxiliary A Yellow 4 Auxiliary B PIN FUNCTION COLOR Orange 1 SensorNet A White 2 28 Vac Red 3 Ground Black 4 28 Vac Yellow 5 SensorNet B PIN FUNCTION COLOR Orange 1 SensorNet A Yellow 2 SensorNet B Black 3 24 Vac A Red 4 Ground White 5 24 Vac B PIN FUNCTI...

Page 5: ...e number buttons to select the dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Reset Dome 4 Press the left zoom focus button line 1 or right zoom focus button line 2 to select the Reset Dome menu option The ADTT16E Touch Tracker sends a request to the selected dome to reboot After a brief delay the controller returns to Camera Control Mode Toggling between Zoom an...

Page 6: ...Max 55 66 77 88 Pan FSR Calibration Values Left Right Up Down Product Code F 7000 0020 0102 Indicates Flash PROM Product Code E 0701 0010 0105 Indicates EEPROM 5 Press Menu to exit Performing SensorNet Ping Test 1 Use the number buttons to select a dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the left zoom focus button line 1 or right zoom...

Reviews: