American Dynamics ADTT16E Touch Tracker Installation Instructions Manual Download Page 2

ADTT16E TOUCH TRACKER CONTROLLER WITH INTELLEX 

8000-2637-02, REV. C 

INSTALLATION INSTRUCTIONS 

2 of 6 

 

 

Parts Required 

ADTT16E Touch Tracker Controller 
Installation Kit  

Part Number 0351-0474-06 

Description Qty. 

Part 

No. 

Modular cable assy 

4.3m  6003-0047-01 

Screw, M2.9x9.5 

5899-0004-102 

Anchor, 4-8x.750 

2880-0083-01 

Screw, #8x1 

2816-7634-44 

Conn, 1x5pos 

2109-0254-04 

Lug, 22-16AWG 

2141-0002 

Cable, 3-cond, 18AWG 

5m 

6002-0024-01 

Interconnect box  

0300-1000-01  

Serial cable, DB9M-DB9F  

6003-0017-05 

Hood, D-Sub, 9pos, cable 

2125-0007-02 

Conn, D-Sub, plug, hsg, 9pos 

2130-0021-01 

Contact, pin, D-Sub, 22-26 AWG  1 

2103-0092-01 

 
 

WARNING:

 

Shock Hazard!

 

Disconnect AC Power to the 
Switch. 

 

CAUTION:

 Static Sensitive Components! 

Follow proper handling procedures to 
prevent component failure. 

 
 

 

Installation Procedure 

1.  Terminate the external interconnect module 

(EIM) at the end of the SensorNet network. See 
the diagram on page 3 or 4. 

 

For more information on the SensorNet 
network, refer to the SensorNet Network Guide 
(PN 8000-0970-01). 

2.  Mount the EIM on a wall or other surface within 

3m (10') of the ADTT16E Touch Tracker. 

3.  Connect the power transformer and SensorNet 

cable to J3 on the EIM. 

4.  Connect the DB9M-DB9F Serial Cable (PN 

6003-0017-05) to the DB9 connectors on the 
EIM and Intellex back panel. Refer to the 
illustrations on pages 3 or 4 for additional 
information. 

5.  Connect the data cable from J1 on the main 

ADTT16E Touch Tracker EIM to the Remote 
port at the rear panel of the multiplexer. 

6.  Connect the modular cable from J2 on EIM to 

the ADTT16E Touch Tracker. 

7.  Connect the SensorNet cable from the dome to 

the terminated EIM. 

8.  Plug the power transformer into a grounded, 

3-wire receptacle. 

 

NOTE:

 If the keypad and backlighting do not 

illuminate when power is applied, unplug each 
power transformer and repeat steps 3 
through 8. 

9.  From the ADTT16E Touch Tracker, press 

Menu

 to configure the software for the Intellex 

system. 

10.  Using the Tracker Ball, page down the screen 

to the 

Config Devices

 menu option. 

11.  Press the zoom/focus button to select the 

Config Devices

 menu option. 

12. Press 

Next

 to the select the appropriate device 

for this installation. See the example screen 
below. 

 

Device = Mux     16
       = POSEM

 

13. Press 

Menu

 to select the device configuration 

and return to the Camera Control mode. 

 
 

!

 

Summary of Contents for ADTT16E Touch Tracker

Page 1: ...ion 3 Intellex 2 0 Connection 4 Calibrating the Tracker Ball 5 Configuring Devices 5 Resetting a Dome 5 Toggling between Zoom and Focus 5 Adjusting V Phase 5 Providing System Information 6 Performing SensorNet Ping Test 6 2005 Sensormatic Electronics Corp About this Guide This installation guide explains the wiring of the ADTT16E Touch Tracker Controller with the Intellex Digital Video Management ...

Page 2: ...all or other surface within 3m 10 of the ADTT16E Touch Tracker 3 Connect the power transformer and SensorNet cable to J3 on the EIM 4 Connect the DB9M DB9F Serial Cable PN 6003 0017 05 to the DB9 connectors on the EIM and Intellex back panel Refer to the illustrations on pages 3 or 4 for additional information 5 Connect the data cable from J1 on the main ADTT16E Touch Tracker EIM to the Remote por...

Page 3: ...und White 5 24 Vac B PIN FUNCTION 5 4 3 2 1 J Box 1 EIM 1 DB9 M RJ45 RJ45 P1 P2 P3 P4 P5 P6 P8 UniCard P3 UniCard P3 ASSY 0301 0340 01 REV 3 2 1 TERMINATED DB9 F P1 P2 P3 P4 P5 P6 P8 3 5 4 J Box 2 Main Touch Tracker Intellex 1 x with DB9 Connector 24 Vac A 24 Vac B Ground Serial Cable PN 6003 0017 05 RPNR00 Terminate E1 on EIM 1 E1 The ma ximum combined SensorNet cable length is 1000 m 3000 5 4 3 ...

Page 4: ...PNR00 Terminate E1 on EIM 1 E1 The maximum combined SensorNet cable length is 1000 m 3000 5 4 3 2 1 COLOR Orange 1 Host A Yellow 2 Host B Orange Auxiliary A Yellow 4 Auxiliary B PIN FUNCTION COLOR Orange 1 SensorNet A White 2 28 Vac Red 3 Ground Black 4 28 Vac Yellow 5 SensorNet B PIN FUNCTION COLOR Orange 1 SensorNet A Yellow 2 SensorNet B Black 3 24 Vac A Red 4 Ground White 5 24 Vac B PIN FUNCTI...

Page 5: ...e number buttons to select the dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Reset Dome 4 Press the left zoom focus button line 1 or right zoom focus button line 2 to select the Reset Dome menu option The ADTT16E Touch Tracker sends a request to the selected dome to reboot After a brief delay the controller returns to Camera Control Mode Toggling between Zoom an...

Page 6: ...Max 55 66 77 88 Pan FSR Calibration Values Left Right Up Down Product Code F 7000 0020 0102 Indicates Flash PROM Product Code E 0701 0010 0105 Indicates EEPROM 5 Press Menu to exit Performing SensorNet Ping Test 1 Use the number buttons to select a dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the left zoom focus button line 1 or right zoom...