American Dynamics ADCA330CN Installation Manual Download Page 8

8

Fixed Color Cameras

Installation Manual

BACK FOCUS ADJUSTMENT

There are two adjustment points accessible from the top and bottom of the camera housing that

are used to adjust the back focal length or picture focus. The range of adjustment allows both

C and CS mount lenses to be used without the need for a spacer ring. To use the back focus

mechanism:
1. Unlock the back focus mechanism using the back focus locking screws on the top and

bottom of the camera.

2. Rotate the backfocus adjustment ring as required. When viewed from the front of the

camera, clockwise adjustment moves the CCD sensor towards the back of the lens;

counterclockwise adjustment moves the CCD sensor away from the back of the lens.

3. Lock the back focus mechanism.

BACK FOCUS

LOCKING SCREW

BACK FOCUS
ADJUSTMENT
RING

INSTALLING FIXED IRIS LENSES

1. Turn the back focus adjustment ring fully counterclockwise (when viewed from the front)—

see 

Back Focus Adjustment

.

2. Fit the lens to the camera.
3. If the lens has a focusing ring fitted, set it to infinity (

¥

) and then adjust the back focus—see

Back Focus Adjustment

.

4. Ensure the Automatic Electronic Shutter (AES) and Automatic Gain Control (AGC) features

are both turned ON.

INSTALLING MANUAL IRIS LENSES

1. Turn the back focus adjustment ring fully counterclockwise (when viewed from the front)—

see 

Back Focus Adjustment

.

2. Fit the lens to the camera.
3. Turn the Automatic Electronic Shutter (AES) and Automatic Gain Control (AGC) features

OFF.

4. If the lens has a focusing ring fitted, set it to infinity (

¥

) and then adjust the back focus—see

Back Focus Adjustment

.

5. With typical scene illumination, set the lens iris for the correct exposure. This can be

achieved either visually, or by using an oscilloscope to set the output of the camera to 1V

peak-peak.

6. Ensure the Automatic Electronic Shutter (AES) and Automatic Gain Control (AGC) features

are both turned ON.

Summary of Contents for ADCA330CN

Page 1: ...70 Fixed Color Cameras ADCA330CN ADCA330CP ADCA470CAFN ADCA470CAFP Installation Manual...

Page 2: ...auto iris lenses All cameras also have an adjustable back focus mechanism and accept C and CS lenses ADCA470 andADCA330 series cameras feature 1 3 CCD Sensor 470 TVL ADCA470 or 330 TVL ADCA330 resolu...

Page 3: ...munications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can...

Page 4: ...onnected Power consumption is less than 4 2 watts VIDEO CONNECTIONS To obtain a video output connect a video coaxial cable terminated with a 75W BNC connector to the BNC socket marked VIDEO OUT on the...

Page 5: ...mics Intellex DVR video file sizes can be decreased by up to 30 When the DVR SAVERTM dip switch is set to ON the image may appear softer though the difference is minimal once compressed in the DVR The...

Page 6: ...e the relatively bright background would cause the camera to reduce its exposure By using the backlight compensation feature it is possible to select a window around the area of interest i e the doorw...

Page 7: ...ll then allow the user to advance or retard the line lock phase trigger point by 180O 360O of adjustment The factory default setting is the zero crossing point To reset the trigger point to the factor...

Page 8: ...back focus adjustment ring fully counterclockwise when viewed from the front see Back Focus Adjustment 2 Fit the lens to the camera 3 If the lens has a focusing ring fitted set it to infinity and the...

Page 9: ...nd then adjust the back focus see Back Focus Adjustment 5 With typical scene illumination set the DC Lens Level adjustment potentiometer on the rear of the camera for the correct exposure This can be...

Page 10: ...photographic mounting bolts 1 4 20 UNC The mounting bracket must be capable of supporting the weight of the camera and its lens In cases where the lens is substantially heavier than the camera it is...

Page 11: ...eo Drive using lens auto sensing feature Automatic Gain Control Selectable on or off Gamma 0 45 fixed White Balance Auto Tracing Framed 2500K to 9500K or Manual with Red and Blue adjust using rear pan...

Page 12: ...tion www americandynamics net 2003 American Dynamics Product specifications subject to change without notice Certain product names mentioned herein may be trade names and or registered trademarks of o...

Reviews: