8
Note:
Terminals 1 (Neutral), 2 (Line), and 3
(Ground) are for incoming 120Vac or 230Vac
source voltage. Terminal 4 is not used.
Table 3 (for 30-watt Illuminators) and Table 4 (for
60-watt Illuminators) list the recommended AWG
wire size for the distance between the power
supply and the Illuminator when using 4-wire
connections.
Table 3. Recommended power wire size for 1020/30-
watt illuminator
AWG
Distance
16
0m - 30.5m (0' -100')
18
0m - 22.9m (0' - 75')
20
0m - 15.2m (0' - 50')
Table 4. Recommended power wire size for 1020/60-
watt illuminator
AWG
Distance
12
0m - 30.5m (0' -100')
14
0m - 22.9m (0' - 75')
16
0m - 15.2m (0' - 50')
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Lamp does
not come on
No 13.5 Vdc to Lamp
Check 120 Vac or
230 Vac source to
power supply
Check twilight switch
operation (if used)
Check power supply
operation
Over-voltage
protection activated
Temperature
protection activated
Check power supply
output < 15 Vdc
Check twilight switch
Poor image
quality on
video monitor
Camera not sensing
IR wavelengths
Camera does not
resolve distant
objects
Check that camera is
sensitive to IR light
Poor connections
causing low DC
voltage
IF YOU ENCOUNTER ANY PROBLEMS
OPERATING THIS UNIT, OR NEED TECHNICAL
ASSISTANCE, CALL OUR TECHNICAL
SUPPORT CENTER AT:
within the United States: 800-442-2225
outside the United States: 914-624-7640