![American Dynamics AD RS-422 Installation And Operation Instructions Manual Download Page 11](http://html1.mh-extra.com/html/american-dynamics/ad-rs-422/ad-rs-422_installation-and-operation-instructions-manual_2923815011.webp)
Model AD2083-02C AD RS-422 Distributor Installation and Operation Instructions
3
Setup using DIP Switches
The AD2083-02C is configured using four 8-position DIP switches (S1, S2, S3, and S4) located on the rear panel
of the unit, and two 8-position DIP switches (S5 and S6) located on the main printed circuit board (PCB) inside the
unit.
Camera Block Assignments
Four 8-position DIP switches (S1, S2, S3, and S4) are located on the rear panel of the unit, as shown in Figure 1.
The settings of these switches determine the cameras associated with the connectors in each of four selective
groups. The active positions for each DIP switch are labeled A, B, C, and D (see Figure 1). Table 1 shows the
switch settings that correspond to camera assignments for all supported domes.
Note
When used with the AD1650 switcher, one AD2083-02C Code Distributor accepts inputs 1-64. A second
AD2083-02C unit is required for inputs 65 through 128.
Table 1 – S1, S2, S3, and S4 Setup
All SpeedDome Models
Video Input
Switch Positions (0=OFF, 1=ON)
Camera #s
A
B
C
D
1-99 0
0
0
0
100-198 0
0
0 1
199-297 0
0
1 0
298-396 0
0
1 1
397-495 0
1
0 0
496-594 0
1
0 1
595-693 0
1
1 0
694-792 0
1
1 1
793-891 1
0
0 0
892-990 1
0
0 1
991-1024 1
0
1 0