American Dynamics 1476-C Installation And Operating Instructions Manual Download Page 13

AD1476

SETUP PROGRAMMING

TITLES

The Titles menu permits the entry of separate titles for each Video
Input.

Figure 19 - Titles Menu

To enter on-screen titles for Video Inputs 1 through 8, select the
CAMERA INPUT entry using the up or down arrow pushbuttons to
position the cursor at the desired camera title.

Using the left/right arrow pushbuttons, position the cursor at the
character to be entered or changed. Eight characters may be entered
for each title. Use the + and  - pushbuttons to increment or decrement
the character at that position. The available alphanumeric characters
are:

ABCDEFGHIJKLMNOPQRSTUVWXYZO1 23456789_ •: ( ? ! ' . )

+-*/=&,

When all entries are displayed as desired, press NEXT to store the
displayed entries and advance to the ALARMS menu.

ALARMS

The Alarms menu is used to set the desired alarm configuration.

NO/NC: 

Displays the normal (not alarmed) status of the external

alarm devices connected to the Alarm Inputs. The alarm numbers 1-8
are displayed above each status entry in the menu.

• O = Normally Open
• C = Normally Closed
• X = Disabled - Alarms from this input ignored.

Use the arrow pushbuttons to position the cursor at the status to be
changed. Use the + or  - pushbuttons to change the entry until the
desired status is shown.

Clear: 

Defines the type of alarm clearance.

• I (Instant): Clears alarms when the alarm input clears.
• D (Delay): Holds alarms 20 seconds after the input clears.
• A (Acknowledge): Holds alarms until acknowledged.

Use the arrow pushbuttons to position the cursor at the CLEAR entry.
Use the + or  - pushbuttons to change the entry until the desired
clearance type is shown.

Freeze: Establishes whether a Quad Display is, or is not, frozen at the
moment of first alarm.

IN = Frozen
OUT = Not Frozen

Use the arrow pushbuttons to position the cursor at the FREEZE entry.
Use the + or - pushbuttons to change the value.

Seq Quad: 

Establishes whether the Quad Display, as programmed on

the Sequences menu, is or is not sequenced with alarmed cameras.

IN = Sequence
OUT = Not Sequenced

Use the arrow pushbuttons to position the cursor at the SEQ QUAD
entry. Use the + or - pushbutton to change the value.

When all entries are displayed as desired, press NEXT to store the
displayed entries and advance to the TIME & DATE Menu.

Figure 20:  Alarms Menu

Summary of Contents for 1476-C

Page 1: ...Model 1476 C SuperQuad HR Installation and Operating Instructions...

Page 2: ...RS 232 5 Video Inputs 6 Video Outputs 7 Front Panel Controls 8 General Operation 9 Quad Operation 9 SuperQuad Operation 9 Video Loss Detection 9 Alarm Handling 9 VCR Playback 10 Setup Programming 10...

Page 3: ...l outputs On screen displays including camera number and 8 character user entered data User setup of full screen camera sequences on the Call output Quad display may be included Manual instant freeze...

Page 4: ...nal jumpers see Figure 2 may need to be reset for specific user requirements These jumpers are factory set for most user needs as indicated below and in Figure 2 Color Filters Jumpers J4 27 The SuperQ...

Page 5: ...ct rating of this relay is 0 6 Amps 120 VAC or 2 0 Amps 30 VAC RS 232 The SuperQuad HR may be controlled via RS 232 connection from a keyboard terminal or computer Refer to page 13 for control of the...

Page 6: ...n Quad A video inputs 5 thru 8 are displayed in Quad B Refer to Figure 4 Four 3 position slide switches located on the rear panel one under each pair of BNC connectors configure the input termination...

Page 7: ...hain is terminated in 75 ohms 5 to 7 Camera Configuration If less than eight video sources are used and you do not wish to have a blank screen in one of the Quads or you wish to see one or more high p...

Page 8: ...ttons FREEZE Alternate depression of this button freezes the currently displayed Quad picture on both the CALL and QUAD Monitor outputs or restores the real time Quad display When the display is froze...

Page 9: ...re alarmed The Alarm pushbutton blinks whether or not alarm handling is enabled The Alarm cameras are identified on the screen by an A The QUAD Monitor displays either the programmed Quad Display or a...

Page 10: ...QUAD output This Loop thru capability provides the user with the ability to view the output from the VCR directly on the Quad monitor for ease of VCR setup Note It the QUAD output is connected to the...

Page 11: ...amming and the ALARMS pushbutton can always acknowledge an alarm Note The unit must be set to operate the way it is intended before the front panel is disabled Unit ID Establishes the SuperQuad Unit I...

Page 12: ...all entries are displayed as desired press NEXT to store the entries and advance to the QUAD DISPLAY menu QUAD DISPLAY The Quad Display menu lets you select the desire configuration of the QUAD Monito...

Page 13: ...rmally Closed X Disabled Alarms from this input ignored Use the arrow pushbuttons to position the cursor at the status to be changed Use the or pushbuttons to change the entry until the desired status...

Page 14: ...and pushbuttons to change the format DATE AND TIME The date and time values are set as three separate fields in each line month day and year for date our minute and second for time Use the arrow push...

Page 15: ...disconnect is received KEYBOARD CONTROL The AD1475RT keyboard can control one or more SuperQuads via the RS 232 interface Dedicated buttons are provided on the keyboard for all SuperQuad functions ex...

Reviews: