MOUNTING
The 1218 Pan unit can be wall or ceiling mounted.
Mounting the Unit from the Ceiling
The 1218 is supplied with a ceiling mount (see Figure 2)
adapter plate bolted to the base. The base has four holes which
accept 6 mm bolts on a 4-inch (101.6 mm) diameter. The unit
can be attached directly to the ceiling by bolting or screwing
through these holes.
Wall Mounting Using the 1391 Mount
Mount the head on a 1391 mount in the following way:
• Three heavy duty screws are recommended for securing the
bracket.
• Bolt the 1218 unit to the bracket using the three 6 mm bolts
and washers supplied as shown in Figure 3. The ceiling
adapter plate is not used when mounting the head to a wall
bracket.
Note: If the unit is mounted upside down, reposition the
platform through 180°. Remember that the directions
of pan and tilt are reversed.
MOUNTING
Figure 3 - Attaching 1218 Pan/Tilt to the 1391 Wall mount
2
Four holes to fit 6 mm bolts
on 4" (101.6 mm) PCD
Three holes to fit 6 mm bolts
on 1.97" (50 mm) PCD
Figure 2 - Attaching 1218 Pan/Tilt to Ceiling mount