9
G. CLEARING CREDIT/CLEARING CYCLE
In Coin Mode, credit can be cleared from the Phase 7 dual microprocessor controller (DMC) computer by
pressing and holding the “PAUSE”
key while entering the following key combination: “HI-HI-HI-LO-LO-
MED”. The combination is the “HI”
key three (3) times followed by the “LO” key two (2) times and then
the “MED” key one (1) time. Wait 1-second for the Phase 7 DMC (computer) to prompt the user with
“CLEAR CREDIT?” If you want to proceed, simultaneously press the “PAUSE”
key and one (1) of the
remaining keys. This will clear the credit. A flowchart of this procedure has been provided in
Section VI
of this
manual.
A cycle in Free Mode can be cleared by first pausing a cycle and then pressing the “PAUSE”
key once again to
clear the cycle.
H. ACCESSING COIN VAULT
The coin vault can be accessed by placing the program switch into the “UP” position. Once the program switch
is in the “UP” position, press the “HI”
key. The Phase 7 DMC (computer) will now display the amount of
money in the coin vault. Press the “HI”
key again and the Phase 7 DMC (computer) will ask to “CLEAR
COIN VAULT TOTAL?” Press “PAUSE”
for “NO” or press “MED” for “YES”.
I. CLEARING FAULT RECORDS AND CREDIT
This feature allows the user to reset the coin vault, clear any credit still available for a cycle and
ALL
fault
records. In order to activate this feature the Phase 7 DMC (computer) needs to be powered down and then
restarted. Immediately after power has been applied to the Phase 7 DMC (computer) press and hold the “PAUSE”
key and “HI”
key simultaneously. The Phase 7 DMC (computer) will prompt the user with the following
message “CLEAR FAULT RECORDS AND CREDIT?” Pressing “PAUSE”
and any other key will indicate a
YES, while pressing any key other than “PAUSE”
will indicate a NO. Once the fault records, coin vault and
credit are cleared, there is no way of restoring this information.
J. WRINKLE GUARD
This program keeps items wrinkle-free when they are not removed from the dryer promptly at the end of the
drying cycle and/or cooling cycle.
When the drying and cooling cycles are completed, the dryer will shut off, the tone will sound, and the liquid
crystal display (L.C.D.) will read “CYCLE DONE”. If the door is not opened, the Phase 7 DMC (computer) will
wait an initial 15 minutes delay time. Once the initial 15 minute delay time has expired, the fan will start and the
basket (tumbler) will rotate (without heat) for an ON time of 15-seconds. When the fan and basket start, the
display will read “WRINKLE GUARD”. Immediately following the 15-second ON time, the Phase 7 DMC
(computer) will go into a 5 minute OFF time at which point it will display “CYCLE DONE”. The Phase 7 DMC
(computer) will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either the doors are opened or
99 minutes have elapsed, whichever comes first. Prior to each ON time, there is a 3-beep warning that the fan
and basket (tumbler) rotation are about to start. The beeps at the end of the Wrinkle Guard Cycle can be
programmed to be ON/OFF. Refer to
page 14
for PL #01 – SELECT BUZZER MODE.