22
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections
Inlet connection ------------ 1" inch N.P.T.
Inlet supply size ------------ 1" inch N.P.T. (minimum)
Btu/hr input (per dryer) --- 310,000
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must
be
consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column (W.C.)
pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. (liquid propane) gas have the gas valve's internal pressure regulator
blocked open so that the gas pressure
must be
regulated upstream of the dryer. The
pressure measured at each gas valve pressure tap
must be
a consistent 10.5 inches water column
(W.C.). There is no regulator or regulation provided in an L.P. dryer. The water column (W.C.)
pressure
must be
regulated at the source (L.P. tank) or an external regulator
must be
added to each
dryer.
* D.M.S. (Drill Material Size of equivalents are as follows:)
Natural Gas ..................... # 10 = .1935
Liquid Propane Gas ...... # 33 = .1130
T
YPE OF
G
AS
Natural
Liquid Propane
L.P.
Conversion
Kit
Part Number
Model
Number
BTU Per
Hour
Rating
Qty.
D.M.S.*
Part
Number
Qty.
D.M.S.*
Part
Number
ML-96HS
310,000
3
#10
140836
3
#33
140855
881498
T
YPE OF
G
AS
Natural
Liquid Propane
Manifold Pressure*
3.5 inches W.C.
10.5 inches W.C.
Inline Pressure
6.0 - 12.0 inches W.C.
10.5 inches W.C.
* Measured at gas valve pressure tap when the gas valve in on.