27
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the left side panel behind top/access control door. In the case of 208 VAC
or 240 VAC, the supply voltage must match the electric service specifications of the
data label
exactly
.
WARNING: 208 VAC AND 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
IMPORTANT:
380, 400, and 416 Volt dryers are built 4-wire only. Customer must contact the
factory to special order 3-wire systems.
ADE-115ES (72 Kw Electric Oven) Reversing, 3ø M otor
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1or RK5 ONLY. Calculate/determine
correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
OVEN SIZE
(Kw)
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
60 Hz
50 Hz
Dual Element
Time Delay
72
208
3ø
3
214
--
*
300
300
72
240
3ø
3
188
190
*
250
250
72
380
3ø
4**
--
118
*
150
150
72
400
3ø
4**
--
112
*
150
150
72
416
3ø
4**
--
108
*
150
150
72
460
3ø
3
98
--
*
125
125
72
480
3ø
3
94
--
*
125
125
72
575
3ø
3
78
--
*
100
110
*AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
(Motor lead wire is recommended.)
**3-wire available.
Summary of Contents for AD-115ES II