background image

American DJ

®

  -  www.americandj.com  - VioMoon LED Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - VioMoon LED Instruction Manual Page 5

Power  Supply:

  The  American  DJ

®

  VioMoon  LED  contains  a  elec-

tronic ballast, which will auto sense the voltage when it is plugged into 
the power source. With the electronic ballast you do not need to worry 
about wall voltage, this unit can be plugged in anywhere. Be sure to 
only use the included I.E.C. power cable supplied with the unit, this 
cable matches the current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture 
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 
fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 
single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 
compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The  VioMoon  LED  can  be  controlled 

via  DMX-512  protocol.  The  VioMoon  LED  has  2 
DMX  channel  modes;  a  1  Channel  mode  and  3 
Channel mode. The DMX address is set electroni-
cally  using  the  controls  on  the  rear  panel  of  the 
unit.  Your  unit  and  your  DMX  controller  require  a 
standard  3-pin  XLR  connector  for  data  input  and 
data output (Figure 1). We recommend Accu-Cable 
DMX cables. If you are making your own cables, be 
sure to use standard 110-120 Ohm shielded cable (This cable may be 

 VioMoon LED 

 

                                           Set Up

Figure 1

purchased at almost all pro lighting stores). Your cables should be made 
with a male and female XLR connector on either end of the cable. Also 
remember that DMX cable must be daisy chained and cannot be split.

 VioMoon LED 

 

                                           Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for VioMoon LED

Page 1: ...DMX channel modes a 1 chan nel mode and 3 channel mode The VioMoon LED has 3 operating modes Sound Active mode Show mode and DMX Control The fix ture can operate as a stand alone unit or in a Master S...

Page 2: ...d into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance VioMoon LED Safety Precautions Ame...

Page 3: ...s on the rear panel of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making yo...

Page 4: ...in a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a pr...

Page 5: ...see page page 13 Mas ter Slave Operation for more information 1 Press the MENU button until SLND is displayed press ENTER MSTR SL 1 or SL 2 will be displayed 2 Press the UP or DOWN buttons until your...

Page 6: ...ons until Yes is displayed press ENTER to confim and exit The fixture will now be in Blackout mode To deactivate Blackout mode select No and press Enter LED With this function you can have the LED dis...

Page 7: ...an explanation of the 2 Slave modes Slave Modes When running fixtures in Master Slave configura tion SL 1 will make the fixture do the opposite to the a fixture set to SL 2 Example If Four fixtures a...

Page 8: ...to wipe down the cooling vents and fan grill 3 Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth e...

Page 9: ...e responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products covered...

Page 10: ...Channel Mode 3 Channel Mode Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days U S Only American DJ Supply American DJ World Headquarters 6122 S Eastern Ave Los Ange...

Reviews: