background image

American DJ

®

  -  www.americandj.com  - TripleFlex Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - TripleFlex Instruction Manual Page 5

Power Supply:

 The American DJ

®

 TripleFlex contains an electronic 

ballast, which will auto sense the voltage when it is plugged into the 

power source. With the electronic ballast you do not need to worry 

about wall voltage, this unit can be plugged in anywhere.  Also be sure 

to only use the included I.E.C. power cable supplied with the unit.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models 

of different manufactures to be linked together and operate from a 

single controller, as long as all fixtures and  the  controller  are  DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The TripleFlex can be controlled via DMX-512 protocol. 

The TripleFlex can be a 4 or 9 channel DMX unit. The DMX address 

is set electronically using the controls on the side 

panel of the unit. Your unit and your DMX control-

ler require a approved DMX-512 110 Ohm Data 

cable for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all professional sound and 

lighting stores). Your cables should be made with a male and female 

 TripleFlex   

                                                     Set Up

Figure 1

XLR connector on either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

 TripleFlex   

 

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for TripleFlex

Page 1: ...he TripleFlex can operate as a stand alone fixture or in a Master Slave configuration The TripleFlex has three operating modes sound active mode show mode and DMX control This fixture is suit able for...

Page 2: ...llen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Trip...

Page 3: ...X control ler require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120...

Page 4: ...Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion TripleFlex Set Up TripleFlex System Menu Chart TripleFlex Installatio...

Page 5: ...t fixture to SL 2 the fixtures will now have contrast movement to each other SHND SH 0 10 Show modes 0 10 Factory programs For show mode to run properly make sure sound active mode is off 1 Tap the ME...

Page 6: ...TER TILT will now be displayed The mirrors will stop and adjust themselves to project an even beam This beam when projected from each unit will allow you to dermine if the units are level with each ot...

Page 7: ...This function allows you to use a Elation universal DMX 512 controller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your indiv...

Page 8: ...COLOR 21 176 183 COLOR 22 184 191 COLOR 23 192 199 COLOR 24 200 207 COLOR 25 208 215 COLOR 26 216 223 COLOR 27 224 231 COLOR 28 232 239 COLOR 29 240 247 COLOR 30 248 255 COLOR 31 TripleFlex 4 Channel...

Page 9: ...club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp output 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Use a brush t...

Page 10: ...design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with re...

Reviews: