background image

•   To reduce the risk of electrical shock or fire, do not expose this unit  
   rain or moisture
•   Do not spill water or other liquids  into or on to your unit.
•   Be sure that the local power outlet match that of the required volt-
   age for your unit.
•   Do not attempt to operate this unit if the power cord has been 
   frayed or broken. 
•   Do not attempt to remove or break off the ground prong from    
   the electrical cord. This prong is used to reduce the risk of electrical  
   shock and fire in case of an internal short.
•   Disconnect from main power before making any type of connection.
•   Do not remove the cover under any conditions. There are no user  
   serviceable parts inside.
•   Never operate this unit when it’s cover is removed.
•   Never plug this unit in to a dimmer pack
•   Always be sure to mount this unit in an area that will allow proper  
   ventilation. Allow about 6” (15cm) between this device and a wall.
•   Do not attempt to operate this unit, if it becomes damaged.
•   This unit is intended for indoor use only, use of this product out-
   doors voids all warranties.
•   During long periods of non-use, disconnect the unit’s main power.
•   Always mount this unit in safe and stable matter.
•   Power-supply cords should be routed so that they are not likely to  
   be walked on or pinched by items placed upon or against them,  
   paying particular attention to cords and plugs, convenience recep- 
   tacles, and the point where they exit from the appliance. 
• Cleaning -The fixture should be cleaned only as recommended by  
   the manufacturer. See page 11 for cleaning details.
•   Heat -The appliance should be situated away from heat sources
     such as radiators, heat registers, stoves, or other appliances    
   (including amplifiers) that produce heat.
•   The fixture should  be serviced by qualified service personnel when:
    A. The power-supply cord or the plug has been damaged.
    B. Objects have fallen on, or liquid has been spilled into the appli 
         ance.
    C. The appliance has been exposed to rain or water.
    D. The appliance does not appear to operate normally or exhibits a  
    

  

 marked change in performance.

 Tempest 250MSD™    

      Safety Precautions

©

American DJ

®

  -  www.americandj.com  - Tempest 250MSD™ Instruction Manual Page 6

©

American DJ

®

  -  www.americandj.com  - Tempest 250MSD™ Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Tempest 250MSD.™ The American DJ

®

 Tempest 250MSD

 is avail-

able in a 120v and 220v version. Because line voltage may vary from 
venue to venue, you should be sure your unit voltages matches the 
wall outlet voltage before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dipswitches in DMX mode:

 This unit uses dipswitches to assign a 

DMX address. Each dipswitch represents a binary value. 
Dipswitch 1 address equals 1 

 

Dipswitch  2 address equals 2 

 

Dipswitch  3 address equals 4 

 

Dipswitch  4 address equals 8 
Dipswitch  5 address equals 16 

 

Dipswitch  6 address equals 32
Dipswitch  7 address equals 64 

 

Dipswitch  8 address equals 128
Dipswitch  9 address equals 254

Dipswitch  10  -  Some  units  omit  dipswitch  10.  When  a  unit  does 
include dipswitch #10, it is usually used for special functions such as 

 Tempest 250MSD™   

 

 

        Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

Summary of Contents for Tempest 250MSD

Page 1: ...return this unit to your dealer without first contacting customer support Customer Support American DJ provides a toll free customer support line to provide set up help and to answer any question sho...

Page 2: ...ecially designed to shield against UV radiation Epileptic Warning Those suffering from epilepsy should avoid looking directly into the lamp at all times Avoid switch the fixture on and off repeatedly...

Page 3: ...ndj com Tempest 250MSD Instruction Manual Page 6 American DJ www americandj com Tempest 250MSD Instruction Manual Page 5 Power Supply Before plugging your unit in be sure the source volt age in your a...

Page 4: ...l Ground Shield 3 Pin XLR to 5 Pin XLR Conversion sound activation Assigning DMX Address Each dipswitch has a preset value A specific DMX address is set by combining the dipswitches that sum your desi...

Page 5: ...the sensitivity turning the knob in the counter clockwise direction will decrease the fixture s sensitivity to sound 4 The optional MINI C Controller may be used with this mode to control a blackout f...

Page 6: ...mpest 250MSD Instruction Manual Page 11 Tempest 250MSD Lamp Replacement Caution Always replace with the exact same type lamp unless oth erwise specified by an authorized American DJ service technician...

Page 7: ...17 252 254 Random Programs 255 Sound Active Tempest 250MSD DMX Traits American DJ www americandj com Tempest 250MSD Instruction Manual Page 14 American DJ www americandj com Tempest 250MSD Instruction...

Page 8: ...erican DJ concludes after inspection affects the reli ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorizatio...

Reviews: