dipswitch 10 it is used for special functions.
Each dipswitch has a preset value. A specific DMX address is set by 

combining the dipswitches that sum your desired value. For example:  

To achieve a DMX address of 21, combine dipswitches 1, 3, and 5. 
Sense dipswitch 1 has a value of 1, dipswitch 3 has a value of 4, and 
dipswitch 5 has a value of 16, the combination of the create a DMX 
value of 21.
Set DMX address 21:       

 

Set DMX address 201:

Dipswitch # 1 = 1            

 

Dipswitch # 1 = 1

Dipswitch # 3 = 4 

 

 

Dipswitch # 4 = 8

Dipswitch # 5 = 16 

 

  

Dipswitch # 7 = 64

 

 

= 21   

            Dipswitch # 8 = 128

   

 

 

 

 

 

 

=  201

Data Cable (DMX Cable) Requirements (For DMX and Master/

Slave Operation):

 The Sunray LED DMX™ can be controlled via DMX-

512 protocol. The American DJ

®

 Sunray LED DMX™ is a two channel 

DMX unit. The DMX address is set on the back panel of the Sunray LED 
DMX™. Your unit and your DMX controller require 
a  standard  3-pin  XLR  connector  for  data  input 
and data output (Figure 1). If you are making your 
own cables, be sure to use standard two conduc-
tor shielded cable (This cable may be purchased 
at almost all pro sound and lighting stores). Your 
cables should be made with a male and female 
XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained 
and can not be split.

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

Sunray LED DMX.™ The American DJ

®

 Sunray LED DMX™ is available 

in a 120v and 220v version. Because line voltage may vary from venue 
to venue, you should be sure your unit voltages matches the wall outlet 

voltage before attempting to operate you fixture.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com

-

pliant. To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dip-switches in DMX mode: 

This unit uses dipswitches to assign a 

DMX address. Each dipswitch represents a binary value. 
Dipswitch 1 address equals 1 

 

Dipswitch 2 address equals 2 

 

Dipswitch 3 address equals 4 

 

Dipswitch 4 address equals 8 
Dipswitch 5 address equals 16 

 

Dipswitch 6 address equals 32
Dipswitch 7 address equals 64 

 

Dipswitch 8 address equals 128
Dipswitch 9 address equals 256
Dipswitch 10 - Some units omit dipswitch 10. When a unit does include 

 Sunray LED DMX™ 

 

 

                        Set Up 

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SP

DMX CHANNEL

Figure 1

 Sunray LED DMX™ 

 

 

                        Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Summary of Contents for Sunray LED DMX

Page 1: ...ntelligent centerpiece This fixture can be used as a stand alone piece or connected in a Master Slave con figuration The unit can also be controlled via DMX controller When used in DMX mode the fixture uses 2 DMX channels Customer Support American DJ provides a toll free customer sup port line to provide set up help and to answer any question should you encounter problems during your set up or ini...

Page 2: ...ways be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power su...

Page 3: ...troller to the fixture DMX data is sent as serial data that trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a sin gle controller as long as all fixtures and the controller...

Page 4: ...blackout See the next page for UC3 controls Universal DMX Control This function allows you to use a uni versal DMX 512 controller such as the Elation DMX Operator or Show Designer to control the DMX traits Operating through a DMX Sunray LED DMX Operation Sunray LED DMX Set Up Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid...

Page 5: ...crew driver in to the fuse holder housing Turn the screwdriver in counter clockwise direction to remove the fuse holder Remove the old fuse and discard it replace the fuse with the same type Insert the fuse holder back into it s housing and turn in clockwise direction to lock the holder in place Sunray LED DMX Cleaning Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and ex...

Page 6: ...products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E American DJ Inc reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplie...

Reviews: