background image

©

American DJ

®

  -  www.americandj.com  - Spherion Tri LED Instruction Manual Page 7

 Spherion Tri LED   

 

                                 Set Up

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Universal DMX Control: 

This function allows you to use a Elation

® 

universal  DMX-512  controller  to  control  the  chases  and  patterns, 
dimmer  and  strobe.  A  DMX  controller  allows  you  to  create  unique 
programs tailored to your individual needs. 
1.  The Spherion Tri LED can be either a 1 or 3 DMX channel fixture.  
 

See page 15 for detailed description of the DMX values and    

 

traits.

2.  To control your fixture in DMX mode, follow the set-up procedures 
 

on pages 6-8 as well as the set-up specifications that are includ-

 

ed with your DMX controller. 

3.  Use the controller’s faders to control the various DMX fixture traits.
4.  This will allow you to create your own programs.
5.  Follow the instructions on page 9 to set the DMX address. 
6.  For longer cable runs (more than a 100 feet) use a terminator on  
 

the last fixture.

7.  For help operating in DMX mode consult the manual included   
 

with your DMX controller.

 Spherion Tri LED                                             DMX Control

©

American DJ

®

  -  www.americandj.com  - Spherion Tri LED Instruction Manual Page 14

Master-Slave Operation 

This function will allow you to link up to 16 

units together and operate without a controller. The units will be sound 
activated. In Master-Slave operation one unit will act as the controlling 
unit and the others will react to the controlling units programs. Any unit 
can act as a Master or as a Slave.
1.   Using approved DMX data cables, daisy chain your units togeth-  
 

er via the XLR connector on the rear of the units. Remember the  

 

Male XLR connector is the input and the Female XLR connector 

 

is the output. The first unit in the chain (master) will use the female  

 

XLR connector only - The last unit in the chain will use the male  

 

XLR connector only. For longer cable runs we suggest a termina- 

 

tor at the last fixture.

2.   On the Master unit find and run your desired operating mode.

3.  On the slave units 

tap the MENU button until “

SLND

” is dis-   

 

played, and Press ENTER. See page 9 under “

SLND

” for more   

 

infomation.

4.   The slave units will now follow the Master unit.

 Spherion Tri LED                     Master-Slave Configuration

Summary of Contents for Spherion Tri LED

Page 1: ...ters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 582 2610 Web www americandj com E mail info americandj com American DJ Europe Junostraat 2 6468 EW Kerkrade Netherlands servic...

Page 2: ...al operation You may also visit us on the web at www americandj com for any comments or suggestions Service Hours are Monday through Friday 8 00 a m to 4 30 p m Pacific Standard Time Voice 800 322 633...

Page 3: ...under warranty or not must be freight pre paid and accompany a return authorization R A number If the unit is under warranty you must provide a copy of your proof of purchase invoice Please contact Am...

Page 4: ...ust be shipped in it s original package No accessories should be shipped with the product If any accessories are shipped with the product American DJ Inc shall have no liability whatsoever for loss of...

Page 5: ...the controls on the rear panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If...

Page 6: ......

Page 7: ...er s faders to control the various DMX fixture traits 4 This will allow you to create your own programs 5 Follow the instructions on page 9 to set the DMX address 6 For longer cable runs more than a 1...

Page 8: ...running time of the fixture 1 Press the MENU button until FHRS is displayed press ENTER 2 The running time of the fixture will now be displayed Press MENU to exit VER With this function you can displa...

Page 9: ...ode 1 Press the either the MENU button until CHND is displayed press ENTER Either 1CH or 3CH will be displayed 2 Press the UP or DOWN buttons to choose your desired DMX mode and press ENTER to confim...

Page 10: ...the MENU button until PROG is displayed press ENTER 2 CoLo will now be displayed press ENTER CoLX will now be displayed X representing a number between 1 7 Use the UP American DJ www americandj com Sp...

Reviews: