background image

Address 06

Slave 2

0 0 6

Slave 3

0 1 1

Address 11

P S 1

Automatic Program1~ Program3

Sound Active Program1~ Program3

Slave 1

0 0 1

Master

P A 1

Address 01

Display Setb

Sonud Active Control

Porgram 1 : Big Angle Program Function
Porgram 2 : Small Angle Program Function
Porgram 3 : Free Angle Program Function

2

Up Key

: DMX Address Up Counter

3 Down Key : DMX Address Down Counter

1

2

3

1 Function Key : Program Or DMX Address Change Key

5 1 2

 ScanTron 250™   

 

 

 

        Operation

©

American DJ

®

  -  www.americandj.com  - ScanTron 250™ Instruction Manual Page 9

Figure 1

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

ScanTron 250.™ The American DJ

®

 ScanTron 250

 is available in a 

120v and 220v version. Because line voltage may vary from venue to 
venue, you should be sure your unit voltages matches the wall outlet 
voltage before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The ScanTron 250™ can be controlled via DMX-512 proto-

col. The ScanTron 250™ is a five channel DMX unit. The DMX address 
is set on the bottom panel of the ScanTron 250.™ Your unit and your 
DMX controller require a standard 3-pin XLR con-
nector for data input and data output (Figure 1). If 
you are making your own cables, be sure to use 
standard two conductor shielded cable (This cable 
may  be  purchased  at  almost  all  pro  sound  and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end of 
the cable. Also remember that DMX cable must be 
daisy chained and can not be split.

 ScanTron 250™   

 

 

 

     

   Set Up

©

American DJ

®

  -  www.americandj.com  - ScanTron 250™ Instruction Manual Page 10

Summary of Contents for ScanTron 250

Page 1: ...d in multiples of four When used as a stand alone unit or when used in multiples linked in a master slave configuration the optional Mini C or Wireless C controller may be used The optional controller...

Page 2: ...roken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from ma...

Page 3: ...ows the menu and operating func tions that you can choose from 6 Lens This is a fully focusing high quality lens Focus the lens by manually turning the lens in a clockwise or counter clockwise direc t...

Page 4: ...you can select You may also choose to run a big angle program or small angle program depending on the size of the dance floor Only use this mode when running a single unit ScanTron 250 Operation Amer...

Page 5: ...e a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a sin gle controller as long as all fixtures and the...

Page 6: ...XLR POWER POWER POWER DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistanc...

Page 7: ...6 23 GOBO 2 24 31 GOBO 3 32 39 GOBO 4 40 47 GOBO 5 48 55 GOBO 6 56 63 GOBO 7 64 71 GOBO 8 72 79 GOBO 9 80 87 GOBO 10 88 95 BLACK OUT 96 103 GOBO SPOT SHAKE 104 111 GOBO 1 SHAKE 112 119 GOBO 2 SHAKE Sc...

Page 8: ...ct same type lamp unless oth erwise specified by an authorized American DJ service technician Replacing with anything other than the specified part can damage your unit and will void your manufactures...

Page 9: ...If any accessories are shipped with the product American DJ shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if...

Page 10: ...Cycle None DMX 5 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and...