Quad Phase Go
DMX Traits
Channel
Value
Function
1 0 - 255 COLOR SELECTION
1 - 16 COLOR 1
17 - 33 COLOR 2
34 - 50 COLOR 3
51 - 67 COLOR 4
68 - 84 COLOR 5
85 - 101 COLOR 6
102 - 118 COLOR 7
119 - 135 COLOR 8
136 - 152 COLOR 9
153 - 169 COLOR 10
170 - 186 COLOR 11
187 - 203 COLOR 12
204 - 220 COLOR 13
221 - 237 COLOR 14
238 - 255 COLOR 15
2 ROTATION
0 - 9 NO ROTATION
10 - 120 CLOCKWISE FAST - SLOW
121 - 134 NO ROTATION
135 - 245 COUNTER-CLOCKWISE
SLOW - FAST
246 - 249 NO ROTATION
250 - 255 SOUND ACTIVE
3 STROBING
0 OFF
1 - 255 STROBING SLOW - FAST
4 SHUTTER OPEN
0 - 15 OFF
16 - 255 OPEN
ADJ Products, LLC - www.adj.com - Quad Phase Go Instruction Manual Page 17
ADJ Products, LLC - www.adj.com - Quad Phase Go Instruction Manual Page 18
Quad Phase Go
Battery Status & Charging
Battery Status:
This function is used to check the life status of the battery.
Plug the fixture in and press the MODE button until “BATT” is
displayed. Use the UP or DOWN buttons to scroll to “STAT”
and press ENTER. The number that is displayed is the remain-
ing battery life. Please do not let the battery fully die, this
severly shortens the life of the battery.
Example: If “50” is displayed, the battery is at half life. If “25” is
displayed, the battery is at 25% life.
NOTE: When the battery is charging or if the battery life is
below 30% the digital display will flash.
Battery Recharge: To recharge the battery, plug the supplied
AC cord into the AC input on the side of the unit and plug the
other end into a matching power supply.
Press the MODE button until “BATT” is displayed, and press
ENTER.
Use the UP or DOWN buttons to scroll to the menu “CHAR”
then press ENTER.
Use the UP or DOWN buttons to scroll to “ON”, and press
ENTER. The after you select “ON” the battery is now being
charged. To stop charging the battery, select “OFF”.
If the battery is being charged, and the unit is not being used,
press the MODE button until “BATT” is displayed, and press
ENTER. Use the UP or DOWN buttons to scroll to “LOAD” and
press ENTER. Select “ON” to keep the LED on, or “OFF” to
blackout the unit.
It takes about 6 hours to reach full charge.
Note: When unplugging the unit from charging and then
applying power via battery, there will be a minimal charge