background image

P

ower Supply:

 The American DJ Micro Wash RGBW is a 100v~240v 

unit.  Because  of  voltage  setup  of  the  unit  you  do  not  have  to  worry 
about  wall  output  voltage.  This  unit  is  compatiable  with  all  wall  out-
puts.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Micro Wash RGBW can be controlled via DMX-512 protocol. The 
Micro  Wash  RGBW  has  6  DMX  channel  modes,  please  see  page  9 
for the different modes. The DMX address is set on the back panel of 
the Micro Wash RGBW. Your unit and your DMX 
controller  require  a  standard  3-pin  XLR  connec-
tor for data input and data output (Figure 1). We 
recommend  Accu-Cable  DMX  cables.  If  you  are 
making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all pro lighting stores). Your 
cables should be made with a male and female 
XLR connector on either end of the cable. Also 
remember that DMX cable must be daisy chained 
and cannot be split.

©

American DJ

®

  -  www.Americandj.com  - Micro Wash RGBW User Manual Page 5

  Micro Wash RGBW                                                   Set Up

©

American DJ

®

  -  www.Americandj.com  - Micro Wash RGBW User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 Micro Wash RGBW 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Micro Wash RGBW

Page 1: ...DMX intelligent high powered LED par can This fix ture can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This unit has five operating modes Sound Active mode Macro mode Auto mode RGB mode and DMX control mode Customer Support American DJ provides a customer support line to provide set up help and to answer any question...

Page 2: ...ttention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 14 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power su...

Page 3: ... Up American DJ www Americandj com Micro Wash RGBW User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and errati...

Page 4: ...XLR microphone cables to link your units together Remember that the Male XLR connector is the input and the Female XLR connector is the ouput The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Set the Master unit to your desired mode or operation 3 For the Slave unit s set the display to DMX mode 3 or 3 Channe...

Page 5: ...E button until 2000 is displayed This is the DMX addressing for the 2 Channel Mode 5 To run the 4 Channel Mode press the MODE button until 3000 is displayed This is the DMX addressing for the 4 Channel Mode 6 To run the 5 Channel Mode press the MODE button until 4000 is displayed This is the DMX addressing for the 5 Channel Mode 7 To run the 7 Channel Mode press the MODE button until 5000 is displ...

Page 6: ...sh RGBW 7 Channel DMX Values Functions Channel 1 2 3 and 4 will not work when Channel 5 is being used Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 BLUE 1 255 0 100 4 WHITE 1 255 0 100 5 MASTER DIMMER 1 255 0 100 Micro Wash RGBW 5 Channel DMX Values Functions Micro Wash RGBW 2 Channel DMX Values Functions Channel Value Function 1 1 255 COLOR MACROS See 1 Channel DMX mode for color...

Page 7: ...Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew Channel Value Function 1 RED 1 255 0 100 2 GREEN 1 255 0 100 3 ...

Page 8: ...s without any obligation to include these changes in any products theretofore man ufactured No warranty whether expressed or implied is given or made with respect to any acces sory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness ...

Reviews: