background image

P

ower  Supply:

  The  American  DJ

®

  Mega  Bar  50RGB™  contains  a 

electronic ballast, which will auto sense the voltage when it is plugged 
into the power source. With the electronic ballast you do not need to 
worry about wall voltage, this unit can be plugged in anywhere.  Also 
be sure to only use the included I.E.C. power cable supplied with the 
unit.

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega Bar 50RGB™ can be a one, two, three, four, five, six, or seven 

channel DMX unit. The DMX address is set on the side panel of the Mega 
Bar 50RGB™. Your unit and your DMX controller require a approved 
DMX-512 110 Ohm Data cable for data input and 
data  output  (Figure  1).  We  recommend  Accu-
Cable DMX cables. If you are making your own 
cables,  be  sure  to  use  standard  110-120  Ohm 
shielded  cable  (This  cable  may  be  purchased 
at  almost  all  professional  sound  and  lighting 
stores). Your cables should be made with a male 
and female XLR connector on either end of the 
cable.  Also  remember  that  DMX  cable  must  be 
daisy chained and cannot be split.

©American DJ®  -  www.americandj.com  - Mega Bar 50RGB™ Instruction Manual Page 5

  Mega Bar 50RGB™                                                    Set Up

©

American DJ®  -  www.americandj.com  - Mega Bar 50RGB™ Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 Mega Bar 50RGB™ 

 

                                  Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Mega Bar 50RGB

Page 1: ...intelligent LED color wash This wash can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX control ler This unit has seven operating mo...

Page 2: ...amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled in...

Page 3: ...B Instruction Manual Page 5 Mega Bar 50RGB Set Up American DJ www americandj com Mega Bar 50RGB Instruction Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own c...

Page 4: ...andard XLR microphone cables to link your units to gether Remember that the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the f...

Page 5: ...individual needs 1 This function will allow you to control each individual fixture s traits with a Elation DMX 512 2 To run your fixture in DMX mode plug in the fixture via the XLR connections to any...

Page 6: ...1 255 0 100 3 BLUE 1 255 0 100 Mega Bar 50RGB DMX Values Functions 2 Channels Channel Value Function 1 COLOR MACROS PLEASE SEE CHANNEL 1 MODE 2 MASTER DIMMER 1 255 0 100 Mega Bar 50RGB DMX Values Func...

Page 7: ...Locate and remove the unit s power cord Once the cord has been removed located the fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out...

Page 8: ...www americandj com Mega Bar 50RGB Instruction Manual Page 15 Mega Bar 50RGB Blue Photometric Chart Mega Bar 50RGB Green Photometric Chart American DJ www americandj com Mega Bar 50RGB Instruction Man...

Page 9: ...sibility of Ameri can DJ Inc under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of American DJ All products covered by this...

Page 10: ...els Warranty 3 Year 1095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice American DJ Supply American...

Reviews: