background image

©

American DJ Supply

®

  -  www.americandj.com  - FREQ 5 Strobe Instruction Manual Page 14

©

American DJ Supply

®

  -  www.americandj.com  - FREQ 5 Strobe Instruction Manual Page 13

  FREQ 5 Strobe                                                    Operation

for Master setting.  

1.  Press the MENU button until 

SHND

” is displayed, and press  

  ENTER.

2.  

Press the UP or DOWN buttons until you find your desired show,  

  press ENTER, then press and hold the MENU button to confirm.  

  Please see page 9 for more info about Show Mode.

3.  The optional UC3 Controller (not included) may be used to con- 

  trol different functions including blackout. See page 14 for UC3  

  controls and functions.

Manual Mode: 

This mode allows a single unit to run a manual set up.  

1.  Press the MENU button until 

MANU

” is displayed, and press  

  ENTER.

2.   Either “

DIMM

” or “

STRO

” will now be displayed. Press the UP or   

  DOWN buttons to switch between either setting.

3.   When you have decided on what setting you would like to adjust  

      first, press the ENTER button. Use the UP and DOWN buttons to  

      make adjustments. Once you have made your desired adjust-    

      ments press ENTER. 

4.   Once you have finished with your adjustments DO NOT leave this  

      submenu. If you press the MENU button, all adjustments will be-  

      lost and you will have to start over.

5.  The optional UC3 Controller (not included) may be used to con- 

  trol different functions including blackout. See page 14 for UC3  

  controls and functions.

  FREQ 5 Strobe                                                UC3 Control

Blackout 

Blackout the unit 

Function 

Synchronous Strobe by auto   

Synchronous Strobe by sound 

  (press and hold the button) 

Select Show 1 – 12

Manual mode 

 )

N

O

 

D

E

L

w

o

h

S

 )

F

F

O

 

D

E

L

e

b

o

rt

S

 

e

d

o

M

Master-Slave Operation: 

This function will allow you to link up to 16 

units together and operate without a controller. In Master-Slave opera-

tion one unit will act as the controlling unit and the others will react to 

the controlling units programs. Any unit can act as a Master or as a 

Slave.

1.   Using appropriate XLR cables, daisy chain your units together via  

  the XLR connector on the rear of the units. Remember the Male  

  XLR connector is the input and the Female XLR connector is the  

  output. The first unit in the chain (master) will use the female XLR 

  con nector only - The last unit in the chain will use the male XLR  

 

con nector  only.  For longer cable runs we suggest a terminator at  

  the last fixture.

2.   Set the Master unit to your desired operational mode. After you  

  have set your desired operational mode, press the MENU button  

 until 

SLND

” is displayed, and Press ENTER. Use the UP or DOWN  

  buttons to find the “

MAST

” setting and press ENTER.

3.  On the slave units 

tap the MENU button until “

SLND

” is display- 

  ed, and Press ENTER. Use the UP or DOWN buttons to switch  

  between “

SL 1

” to “

SL 15

”. Once you have made your choice,    

  press ENTER. For more info see page 8.

4.   The slave units will now follow the Master unit.

5.  The optional UC3 Controller (not included) may be used to con- 

  trol different functions including blackout. See UC3 Control below.

  FREQ 5 Strobe                                   Master-Slave Set Up

Summary of Contents for FREQ 5 Strobe

Page 1: ...unit has 4 operating modes Sound Active with adjustable sound sensitivity Show Mode Manual Mode or DMX Control This unit can be used as a stand alone fixture or in a Master Slave configuration This fi...

Page 2: ...s Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qua...

Page 3: ...ble must be daisy chained and cannot be split FREQ 5 Strobe Set Up Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do...

Page 4: ...let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 1CH 2CH 5CH or 7CH will be dis played 2 Press the UP or DOWN buttons to find your...

Page 5: ...y control 1 Press the MENU button until SENS is displayed press ENTER 2 The display will show a number between 0 100 Press the UP or DOWN buttons to adjust the sound sensitivity 0 being the least sens...

Page 6: ...Strobe has 4 DMX Channel Modes 1 Channel Mode 2 Channel Mode 5 Channel Mode 7 Channel Mode See pages 15 16 for a detailed description of the DMX traits 2 To control your fixture in DMX mode follow the...

Page 7: ...Control Blackout Blackout the unit Function Synchronous Strobe by auto Synchronous Strobe by sound press and hold the button Select Show 1 12 Manual mode N O D E L w o h S F F O D E L e b o r t S e d...

Page 8: ...NCTION 240 247 SOUND ACTIVE STROBING 248 255 NO FUNCTION FREQ 5 Strobe Photometric Chart FREQ 5 Strobe 1 Channel Mode Channel Value Function 1 SHOWS 0 7 BLACKOUT 8 27 SHOW 1 28 47 SHOW 2 48 67 SHOW 3...

Page 9: ...nc shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the prod...

Page 10: ...tage 100V 240V 50 60Hz LEDs 5 x 5W White LEDs Power Consumption 28W Fuse 7Amp Power Cord Daisy Chain 13 Fixtures Max Weight 5lbs 2Kgs Dimensions 12 L x 5 5 W x 5 5 H 302 x 140 x 140mm Colors White DMX...

Reviews: