background image

P

ower Supply:

 The American DJ Flat Par Tri7 contains a electronic 

ballast, which will auto sense the voltage when it is plugged into the 
power  source.  With  the  electronic  ballast  you  do  not  need  to  worry 
about wall voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Flat Par Tri7 can be controlled via DMX-512 protocol. The Flat Par 
Tri7  has  7  DMX  channel  modes,  please  see  page  9  for  the  different 
modes. The DMX address is set on the back panel of the Flat Par Tri7. 
Your unit and your DMX controller require a stan-
dard 3-pin XLR connector for data input and data 
output  (Figure  1).  We  recommend  Accu-Cable 
DMX cables. If you are making your own cables, 
be  sure  to  use  standard  110-120  Ohm  shielded 
cable (This cable may be purchased at almost all 
pro lighting stores). Your cables should be made 
with a male and female XLR connector on either 
end of the cable. Also remember that DMX cable 
must be daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

©

American DJ

®

  -  www.Americandj.com  - Flat Par Tri7 User Manual Page 5

  Flat Par Tri7                                                              Set Up

©

American DJ

®

  -  www.Americandj.com  - Flat Par Tri7 User Manual Page 6

Figure 1

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 Flat Par Tri7 

 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Flat Par Tri18

Page 1: ...gent high powered LED par fixture This fixture can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This wash has five oper...

Page 2: ...st them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 17 for cleaning details Heat The applia...

Page 3: ...g your own American DJ www Americandj com Flat Par Tri7 User Manual Page 5 Flat Par Tri7 Set Up American DJ www Americandj com Flat Par Tri7 User Manual Page 6 Figure 1 cables Do not use the ground lu...

Page 4: ...emale XLR connector only The last unit in the chain will use the male XLR connector only 2 Connect the first Slave unit to the Master 3 Set the Master unit to your desired mode of operation The Slave...

Page 5: ...traits 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller 2 To run your fixture in DMX mode press the MODE button until A XXX is displayed X...

Page 6: ...R G B Press either one of these buttons and the press the or to adjust the brightness and Use these buttons to adjust the flash rate speed of the Auto Run sound sensitivity and program selection DMX C...

Page 7: ...TER DIMMER 1 255 0 100 Flat Par Tri7 1 Channel DMX Values Functions Channel Value Function 1 COLOR MACROS 1 7 BASTARD AMBER 8 15 MEDIUM AMBER 16 23 PALE AMBER GOLD 24 31 GALLO GOLD 32 39 GOLDEN AMBER...

Page 8: ...t Par Tri7 7 Channel DMX Values Functions Channels 1 2 and 3 will not work when Channel 4 is being used When using Channel 6 values 128 239 Channel 5 will control the speed of the programs When using...

Page 9: ...implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no war...

Page 10: ...Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice American DJ Supply American DJ World Headquarters 6122 S...

Reviews: