background image

P

ower Supply:

 The American DJ Flat Par Tri7X contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Flat Par Tri7X can be controlled via DMX-512 protocol. The Flat Par 

Tri7X has 7 DMX channel modes, please see page 9 for the different DMX 

modes. The DMX address is set on the back panel of the Flat Par Tri7X. 

Your unit and your DMX controller require a stan-

dard 3-pin XLR connector for data input and data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all 

pro lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

©

American DJ

®

  -  www.Americandj.com  - Flat Par Tri7X User Manual Page 5

  Flat Par Tri7X                                                           Set Up

©

American DJ

®

  -  www.Americandj.com  - Flat Par Tri7X User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 Flat Par Tri7X 

 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Flat Par CWWW18

Page 1: ...at Par Tri7X is a DMX intelligent high powered LED par fixture This fixture can be used in a stand alone mode or connected in a Master Slave configuration This wash has five operating modes Sound Acti...

Page 2: ...attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 18 for cleaning details Heat The appliance should be situated aw...

Page 3: ...Manual Page 5 Flat Par Tri7X Set Up American DJ www Americandj com Flat Par Tri7X User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the...

Page 4: ...sound 3 Press the SET UP button to adjust the sound sensitivity SJ X should be displayed Use the UP or DOWN buttons to adjust the sen sitivity SJ 1 is the lowest sensitivity SJ 8 is the highest Stati...

Page 5: ...MODE button until Ch 07 is displayed This is the 7 Channel DMX Mode 4 Please see pages 13 16 for DMX values and traits 5 After you have chosen your desired DMX Channel mode plug in the fixture via th...

Page 6: ...ample Set DMX Address 1 Press S 0 0 1 Set DMX Address 245 Press S 2 4 5 R G B Press either one of these buttons and the press the or to adjust the brightness and Use these buttons to adjust the flash...

Page 7: ...ASTER DIMMER 1 255 0 100 Flat Par Tri7X 1 Channel DMX Values Functions Channel Value Function 1 COLOR MACROS 1 7 BASTARD AMBER 8 15 MEDIUM AMBER 16 23 PALE AMBER GOLD 24 31 GALLO GOLD 32 39 GOLDEN AMB...

Page 8: ...8 192 199 COLOR CHANGE 1 200 207 COLOR CHANGE 2 208 215 COLOR CHANGE 3 216 223 COLOR CHANGE 4 224 231 COLOR CHANGE 5 232 239 COLOR CHANGE 6 240 247 SOUND ACTIVE MODE 1 248 255 SOUND ACTIVE MODE 2 7 MA...

Page 9: ...ource Remove the power cord from the unit Once the cord has been removed you will find that the fuse holder is located inside the power socket Insert a flat head screw driver into the power socket and...

Page 10: ...nspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the American DJ Inc factory unless prior written authorization was issued to purchase...

Reviews: