background image

©

American DJ Supply

®

  -  www.americandj.com  - Electra 250™ Instruction Manual Page 6

©

American DJ Supply

®

  -  www.americandj.com  - Electra 250™ Instruction Manual Page 5

Trouble Shooting:

 

Listed  below  are  a  few  common  problems  that 

you may encounter, with solutions.

No light output from the unit;

1.  Be sure you have connected your unit into a standard    
     110V wall outlet.  
2.  Be sure the external breaker has not popped. The breaker is locat- 
     ed on the rear panel. 
3.  Remove the lamp cover and be sure the lamp is seated 
     in its socket properly. Occasionally lamps become loose 
     during shipping be sure the lamp is push in to its socket 
     all the way. 

 

Unit does not respond to sound;

1.  Be sure the unit's mode switch is in the "I" position, this is 
     the only mode that allows the unit to operate in sound 
     active mode.  
2.  Low frequencies (bass) should cause the unit to react to 
     sound. Tapping on the microphone, quiet or high 
     pitched sounds may not activate the unit.  

  Electra 250™    

 

         Lamp Replacement

This  fixture  is  fitted  with  halogen  lamps  which  are 
highly  susceptible  to  damage  if  improperly  han-
dled.  Never  touch  lamp  with  your  bare  fingers  as 
the oil from your hands will shorten lamp life. Also, 
never  move  the  fixture  until  the  lamps  have  had 
ample time to cool. Remember, lamps are not cov-
ered under warranty conditions.

  Electra 250™    

 

 

   Trouble Shooting

Caution:

 

Always replace with the exact same type lamp, unless oth-

erwise specified by an authorized American DJ

®

 technician. Replace 

with anything other than the specified part can damage your unit and 
will void your manufactures warranty.

Warning: 

If  after  you  have  replaced  the  lamp  or  reset  the  breaker 

and  you  continue  to  blow  either  one,  STOP  using  the  unit.  Contact 
customer support for further instructions, you may have to return the 
unit for servicing. Continuing to use the unit may cause serious dam-
age.

Lamp  Replacement:

  Caution!  Never  open  the  unit  when  in  use. 

Always disconnect the main power and allow the fixture ample time 
to cool before attempting to replace the lamp. Lamp replacement has 
been made simple by incorporating a split dome that is retained by 
thumb  screws. 

Again,  please  remember  to  always  replace  with  the 

exact same type lamp. 

1.   Be sure to follow the proper procedures when handling halogen 
 

lamps. 

Never touch the new lamp with your bare fingers.

2.   Unscrew the two thumb screws located on the bottom front of  
 

the unit. 

3.   Once the thumb screws have been removed, pull the lamp  

 

 

assembly cover plate up to expose the lamp. 

4.   Remove and replace the lamp with an exact match.
5.   Reassemble in reverse order.

  Electra 250™    

 

 

 

       Cleaning

Fixture Cleaning:

 Due to fog residue, smoke, and dust cleaning the 

internal and external optical lenses must be carried out periodically to 
optimize light output.  
1.  Use normal glass cleaner and a soft cloth to wipe down the 
     outside casing.
2.  Use a brush to wipe down the fan grill.
3.  Clean the external optics with glass cleaner and a soft 
     cloth every 20 days.
4.  Clean the internal optics with glass cleaner and a soft cloth 
     every 30-60 days.
5.  Always be sure to dry all parts completely before plugging 
     the unit back in.
Cleaning  frequency  depends  on  the  environment  in  which  the  fix-
ture operates (I.e. smoke, fog residue, dust, dew). In heavy club use 
we  recommend  cleaning  on  a  monthly  basis.  Periodic  cleaning  will 
ensure longevity, and crisp output.

Reviews: