Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

DJ Scan 250 EX.™ The American DJ

®

 DJ Scan 250 EX

 is available 

in a 120v and 220v version. Because line voltage may vary from venue 

to venue, you should be sure your unit voltage matches the wall outlet 

voltage before attempting to operate you fixture.  Also be sure to only 

use the included I.E.C. power cable supplied with the unit, this cable 
matches the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix

-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The  DJ  Scan  250 

EX™ can be controlled via DMX-512 protocol. The 
DJ  Scan  250  EX™  a  five  channel  DMX  unit.  The 

DMX  address  is  set  electronically  using  the  con-
trols  on  the  side  panel  of  the  unit.  Your  unit  and 
your DMX controller require a standard 3-pin XLR 
connector  for  data  input  and  data  output  (Figure 

1). If you are making your own cables, be sure to use standard two 

 DJ Scan 250 EX™  

                                           Set Up

Figure 1

conductor shielded cable (This cable may be purchased at almost all 
professional sound and lighting stores). Your cables should be made 
with a male and female XLR connector on either end of the cable. Also 
remember that DMX cable must be daisy chained and cannot be split.

 DJ Scan 250 EX™  

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for DJ Scan 250 EX

Page 1: ...lone Master Slave configuration or DMX controlled The DJ Scan 250 EX can be used as a stand alone sound active fixture or used in multiples linked in a master slave configuration For best results use...

Page 2: ...spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance DJ Scan 250 EX Safety Preca...

Page 3: ...MX unit The DMX address is set electronically using the con trols on the side panel of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output...

Page 4: ...Address Setting 1 Tap the MENU UP or DOWN buttons until ADDR is dis played press ENTER 2 A number between 1 512 will be displayed and flashing Press the UP or DOWN buttons to find your desired address...

Page 5: ...irm and exit I DSP This function will reverse the display 180 1 Tap the MENU button until I DSP is displayed press ENTER 2 Press ENTER to flip the display Press ENTER to flip it again To save the adju...

Page 6: ...ing the knob on the top of the fixture 2 The optional UC3 Controller not included may be used to con trol different functions including blackout DJ Scan 250 EX Operation DJ Scan 250 EX Operation Maste...

Page 7: ...pport for further instructions you may have to return the unit for servicing Continuing to use the unit may cause serious damage Caution Never open the unit when in use Always disconnect the main powe...

Page 8: ...ay not activate the unit Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cle...

Page 9: ...le responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products covere...

Page 10: ...n Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and improvements in the design of this unit and this manual are subject to change with...

Reviews: