background image

©

American DJ

®

  -  www.americandj.com - Atmospheric RG LED Instruction Manual Page 10

  Atmospheric RG LED    

 

                       Set Up

  Atmospheric RG LED    

 

                       Set Up

a male and female XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained and cannot be split.

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

©

American DJ

®

  -  www.americandj.com - Atmospheric RG LED Instruction Manual Page 9

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

Figure 4

1

2

3

Termination reduces signal errors and

avoids signal transmission problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

Summary of Contents for Atmospheric RG LED

Page 1: ...a Master Slave configuration The Atmospheric RG LED has three operating modes sound active mode show mode or it can be controlled via DMX For best results use fog or special effects smoke to enhance t...

Page 2: ...ower Always mount this unit in safe and stable matter Power cords should be routed so they are not likely to be walked on pinched by items placed upon or against them Cleaning The fixture should be cl...

Page 3: ...irect eye exposure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance...

Page 4: ...ddressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle Therefore the first fixture controlled by the con...

Page 5: ...not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the sh...

Page 6: ...ENU button for at least 3 sec onds SLND This will let you set unit as a slave in a master slave configuration 1 Press the MENU button until SLND is displayed press ENTER Either SL 1 or SL 2 will be di...

Page 7: ...s to confirm LED With this function the LED display will turn off after 2 minutes 1 Press the MENU button until LED is displayed press ENTER 2 Either ON or OFF will now be displayed Press the UP or DO...

Page 8: ...1 Press the MENU button until SHND is displayed and press ENTER 2 Press the UP or DOWN buttons until you find your desired show press ENTER to confirm and then hold MENU for at least 2 3 sec onds 3 Th...

Page 9: ...ys 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates I e smoke fog residue dust dew In heavy use...

Page 10: ...include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to...

Reviews: