background image

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

64B LED PRO. The American DJ

®

 64B LED PRO is available in a 120v 

and 220v version. Because line voltage may vary from venue to venue, 
you should be sure your unit voltages matches the wall outlet voltage 

before attempting to operate you fixture.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli

-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The 64B LED PRO can be controlled via DMX-512 protocol. The 64B 
LED  PRO  can  be  a  three,  six,  or  seven  channel  DMX  unit.  The  DMX 

address is set on the back panel of the 64B LED PRO. Your unit and 
your DMX controller require a standard 3-pin XLR 
connector for data input and data output (Figure 

1). If you are making your own cables, be sure to 

use standard two conductor shielded cable (This 
cable may be purchased at almost all pro sound 
and lighting stores). Your cables should be made 
with a male and female XLR connector on either 
end of the cable. Also remember that DMX cable 
must be daisy chained and can not be split.

©American DJ®  -  www.americandj.com  - 64B LED PRO Instruction Manual Page 5

  64B LED PRO                                                            Set Up

©

American DJ Supply

®

  -  www.americandj.com  - 64B LED PRO Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 64B LED PRO 

 

                                            Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for 64B LED PRO

Page 1: ...ixtures The 64B LED PRO is a DMX intelligent LED Par Can This Par Can is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or in a Master Slave configura tion The unit can also be controlled via DMX controller Customer Support American DJ provides a toll free customer sup port line to provide set up help and to answer any questio...

Page 2: ...ufacturer See page 12 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The ap...

Page 3: ... 64B LED PRO Instruction Manual Page 5 64B LED PRO Set Up American DJ Supply www americandj com 64B LED PRO Instruction Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer ca...

Page 4: ...until A is dis played Sound Active Mode In this mode the 64B LED PRO will react to sound changing and fad ing through the different colors 1 Plug the fixture in and press the MODE button until S XX is dis played XX 00 31 which is adjustable sound sensitivity levels 2 The fixture will now change via sound You can adjust the sound sensitivity by pressing the UP and DOWN buttons The sound sen sitivit...

Page 5: ... create their own programs tailored to their own individual needs Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs This function also allows you to use your fixtures as spot lights 1 This function will allow you to control each individual fixture s traits with a standard Elation DMX 512 controller 2 The 64B LED PRO use...

Page 6: ...B LED PRO Instruction Manual Page 11 American DJ Supply www americandj com 64B LED PRO Instruction Manual Page 12 Channel Value Function 1 0 255 RED 0 100 2 0 255 GREEN 0 100 3 0 255 BLUE 0 100 4 0 7 NOTHING 8 255 COLOR MACRO 5 0 15 NOTHING 16 255 STROBING MACRO SPEED 6 0 31 NOTHING 32 63 DIM BRIGHT 64 95 BRIGHT DIM 96 127 DIM BRIGHT DIM 128 159 COLOR MIXING 160 191 3 COLOR CHANGE 192 223 7 COLOR ...

Page 7: ...ervice and repair labor by reason of defects in material or workmanship The sole responsibility of Ameri can DJ Inc under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of American DJ All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E American DJ Inc rese...

Reviews: