background image

Unpacking:

Every  DJ  Scan  250HP™  has  been  thoroughly  tested  and  has  been 
shipped  in  perfect  operating  condition,  there  is  no  assembly  neces-
sary.  Carefully  check  the  shipping  carton  for  damage  that  may  have 
occurred during shipping. If the carton appears to be damaged, care-
fully inspect your unit for any damage and be sure all equipment nec-
essary to operate the unit has arrived intact. In case damage has been 
found or parts are missing, please contact our toll free customer sup-
port number for further instructions, please do not return the unit to 
your dealer.

Power Supply:

Before plugging your unit in be sure the source voltage in your area 
matches the required voltage for your American DJ

®

 DJ Scan 250HP.™ 

The American DJ

®

 DJ Scan 250HP

 is available in a 120v and 220v ver-

sion. Because line voltage may vary from venue to venue, you should 
be sure to plug your unit into a matching wall outlet before attempting 
to operate you controller.  

Data Cable (DMX Cable) Requirements:

Your controller and packs require a standard 3-pin XLR connector for 
DMX data input and DMX data output (Figure 1).  If you are making your 
own cables be sure to use standard two conductor shielded cable (This 
cable may be purchased at almost all pro sound and lighting stores).  
Your cables should be made with a male and female XLR connector on 
either end of the cable.   Also remember that DMX cable must be daisy 
chained and can not be “Y-d” or split.

Notice:

 

 Do not use the ground lug on the XLR connector.  Do  not con-

nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the  XLR’s outer casing.  Grounding 
the shield could cause a short circuit and erratic behavior.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 IN

CONNECTOR

3 PIN

DMX512 OUT

CONTROLLER

CONNECTOR

3 PIN

©

American DJ Supply

®

  -  www.americandj.com  - DJ Scan 250HP™ User Manual Page 5

  

DJ Scan 250HP™  

 

 

 

              Set Up

Figure 2

  

DJ Scan 250HP™  

 

 

 

              Set Up

©

American DJ Supply

®

  -  www.americandj.com  - DJ Scan 250HP™ User Manual Page 6

Notice:

 Be sure to follow figures two and three when making your own 

cables. 

Special Note: Line Termination.

  

When longer runs of cable are used, you may need to use a terminator 
on the last unit to avoid erratic behavior. A terminator is a 90-120 ohm 
1/4 watt resistor which is connected between pins 2 and 3 of a male 
XLR connector (DATA - and DATA +). This unit is inserted in the female 
XLR  connector  of  the  last  unit  in  your  daisy  chain  to  terminate  the 
line.  Using a cable terminator will decrease the possibilities of erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

  

DJ Scan 250HP™  

 

 

        DMX Addressing 

DMX CHANNEL

1 2 3

5

4

7

9

8

6

ON

1     4    16   64  256

2     8    32  128

DMX is short for Digital Multiplex. This is a universal binary language 
used  as  a  form  of  communication  between  intelligent  fixtures.  Each 
dipswitch represents a binary value.

Dipswitch 1 address equals 1   
Dipswitch 2 address equals 2   
Dipswitch 3 address equals 4   
Dipswitch 4 address equals 8 
Dipswitch 5 address equals 16   
Dipswitch 6 address equals 32
Dipswitch 7 address equals 64   
Dipswitch 8 address equals 128
Dipswitch 9 address equals 256

Figure 3

Figure 3

Summary of Contents for 250HP

Page 1: ...americandj com for any comments or suggestions Toll free customer service hours are Monday through Friday 9 00 a m to 5 30 p m Paci c Standard Time Voice 800 322 6337 Fax 323 582 2610 E mail support...

Page 2: ...units will react to sound and fol low several built in programs Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required volt age for...

Page 3: ...MX512 OUT CONTROLLER CONNECTOR 3 PIN American DJ Supply www americandj com DJ Scan 250HP User Manual Page 5 DJ Scan 250HP Set Up Figure 2 DJ Scan 250HP Set Up American DJ Supply www americandj com DJ...

Page 4: ...olor and channel 4 Gobos 4 To run your fixture in DMX mode plug in the fixture via the XLR DJ Scan 250HP Operating Instructions DJ Scan 250HP Operating Instructions American DJ Supply www americandj c...

Page 5: ...basic controller MINI C features DJ Scan 250HP Optional Remote The MINI C controller may be purchased separately allowing you to control the main unit and any others connected to it while it is in sta...

Page 6: ...y a return authorization R A number If the unit is under warranty you must provide a copy of your proof of purchase invoice Please contact American DJ cus tomer support for a R A number DJ Scan 250HP...

Page 7: ...AKE 154 161 GOBO 7 metal 162 175 GOBO 7 SHAKE 176 183 GOBO 8 metal 184 197 GOBO 8 SHAKE 198 205 GOBO 9 metal 206 219 GOBO 9 SHAKE 220 227 GOBO 10 metal 228 241 GOBO 10 SHAKE 242 249 BLACK OUT 250 255...

Page 8: ...workmanship The sole responsibility of American DJ under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of American DJ All p...

Reviews: