20
3.6 – Functional Description for the AC111, AC115 and AC125
1.
Dispense
This machine dispenses tickets and coins as change.
2.
Payment
The machine accepts payment in the form of cash only.
3.7 – Out-of-Service Conditions & Error Codes for the AC111, AC115
and AC125
System
Failures
Below are conditions that will cause the machine to go into an
“Out-of-Service” mode. While in this mode the out-of-service
light will be illuminated and the machine will not accept any
payment.
Note: These error messages will be displayed on the LCD
display in the form of an alternating message of “Fail”,
current “Total” counter, followed by the error message.
Ticket
Dispenser
Ticket Dispenser Error Conditions
Ticket
Timeout
The ticket dispenser does not have specific sensors for
monitoring when the tickets run out. Instead, the main logic
board reads its optical notch sensor output and applies a
time-out to determine when the ticket bin is out of tickets.
During normal operation, the logic board turns on the
dispenser and monitors the notch sensor output to turn it off
when the correct number of tickets has been dispensed. If too
much time passes before a notch is read, the bin is deemed to
be out of tickets and the
Ticket Timeout
error message is
displayed.
Bill
Validator
Bill Validator Error Conditions.
Validat.
Full
The Bill Stacker is full of bills and should be emptied.
Validat.
Motor
Validator stacker/transport motor has failed. Repair or
replace the bill validator.
Validat.
Sensor
Sensor failure. Check for dirty sensors. Repair or replace the
validator.
Validat.
CheckSum
Indicates error with the firmware file stored on validator main
board. Repair or replace the bill validator.