4
B.
Plug the male end into the AC wall outlet.
Do not
use an extension cord unless allowed by the
building electrical code
.
C.
Important:
Attach the line cord clamp to the line
cord. Verify it is at the right length and that the line
cord is not rubbing against any sharp edges or is
being strained in any way. Then mount the line cord
clamp to the studs at the hole. Tighten securely.
Installation is finished and you can proceed to the
“Filling the Hopper” section.
18.
In order to continue you will need to purchase electrical
cable conduit, a standard 3-prong AC wall outlet and 12-
gauge wire. We highly recommend HIRING a qualified
electrician to perform the following!
A.
Install the conduit box on the conduit entering the
cabinet in the lower right side of the cabinet.
B.
Secure the 3 wires (hot, neutral, and ground) to the
AC wall outlet and the ground wire should also be
directly attached to the cabinet ground terminal.
C.
Connect the AC line cord into the bottom of the main
logic board.
D.
Plug the male end into the AC outlet just installed.
E.
Properly fold the line cord to avoid sharp corners and
any other damage.
19. Proceed to the “Filling the Hopper” section.
FILLING THE HOPPER
When the hopper has less than 40 - 50 coins left in it the red
“Empty” LED will light on the front of the changer. If you
have disconnected your LED, make sure the orange wire is
going to the terminal on the LED that has the red positive
mark next to it. Whenever the “Empty” LED is “ON” the
validator is disabled and it will no longer accept bills.
1.
Turn OFF the power on the main logic board.
2.
Slide the hopper out from the cabinet and insert the coins
through the opening on the top.
There must be at least
enough coins to cover the two gold plates at the bottom
of the hopper
.
(Somewhere between 40 and 1000 coins
minimum to maximum
.)
3.
Slide the hopper back into the hopper plate.
Do not use
excessive force!
4.
Turn “ON” the power switch. The “Empty” LED is now
off and the bill validator is ready to accept bills.
USING THE DUMP MODE TO EMPTY THE HOPPER
1.
Open the cabinet door.
2.
Turn OFF the POWER switch.
3.
Place a suitable container in front of the hopper to catch
the coins.
4.
Press and hold the “DUMP” button on the upper left
corner of the Main Logic Board. Turn ON the Power
switch. The red LED on the main logic board will come
on then go off. Once the red LED goes off, release the
“DUMP” button. If it is not released within two seconds,
the “DUMP” mode is canceled as a security feature. The
hopper will dispense coins until the POWER switch is
turned OFF. If the Red LED on the Main Logic Board is
not flashing 3-5 times per second the dump mode was not
accessed. Please try again.
FUSES
High voltage fuse:
This is the primary transformer AC fuse
for the main logic board and the validator. Any direct short of
the Transformer or validator will cause this fuse to blow.
Replace this fuse with a 2-½ amp AS fuse only.
REPLACING THIS FUSE WITH ANYTHING OTHER
THAN A 2 ½ AMP “AS” MAY RESULT IN A FIRE OR AN
1
0
…
…
…
.
.
…
…
C
4
0
FIGURE #1 MAIN LOGIC BOARD
Transformer
Bill Validator
Harness
Connector (s)
AC Power
Connector
2-1/2 Amp
Fuse
On / Off
Switch
EPROM
Dump
Button
Hopper
Harness
Output
Connector