#1431hrv-4-08
4537 NORTHGATE COURT, SARASOTA, FL 34234-2124, USA
TEL:
941-351-3441 FAX: 941-351-3442
www.americanaldes.com eml: [email protected]
PRODUCT
SPECIFICATIONS
AND ENGINEERING
INFORMATION
-----
SUBMITTAL DATA
MATHEWS GRAPHIC DESIGN - 941-358-0862
THERMALLY CONDUCTIVE,
PATENTED ALUMINUM CORE
The cross-flow heat recovery core
transfers heat between the two air-
streams. It is easily removed for
cleaning or service.
MOTORS AND BLOWERS
Each air stream has an indepen-
dent motorized impeller. 3 speed
operation 120VAC
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four rein-
forced polyester straps that are supplied with the unit.
DEFROST
Recirculating damper defrost system. Exhaust air is periodically cir-
culated through the unit to defrost the core.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corro-
sion resistance. Insulated to prevent exterior condensation. Drain
connections- 1/2" (12 mm) OD.
CONTROLS - HRV System Control
HRV defaults to LOW SPEED when plugged in. HIGH SPEED is ac-
cessible by connecting remote controls to designated terminals in-
side electrical box of HRV.
Standard LOW SPEED SETTING can be increased by manipulating
switches in electrical box. OFF/HIGH speed operation also available
by manipulating switches.
WEIGHT
42 lbs. (19 kg.)
SHIPPING WEIGHT
45 lbs. (20.5 kg.)
ORDERING INFORMATION
PART NUMBER: 28 051
OPTIONAL ACCESSORIES:
28 884
20 Minute Fan timer
-- White, Decora style (3 wire) 20
gauge wire (min.) 100' length (max.)
28 998
60 min. Twist Timer
with hold, white Decora style
22 025
Weather Hoods
, 2 - 5 (125mm) c/w 1/4 (6mm) screen
28 883
Dehumidistat Ventilation Control
- Dehumidistat with
ON/OFF
28 882
Dehumidistat Control
- Dehumidistat
All units conform to CSA and UL standards.
DUCT CONNECTIONS
5" duct connections.
DIMENSIONS
inches
PERFORMANCE
E.S.P. (in.wg.)
CFM
L/S
0.1
143
68
0.2
138
65
0.3
132
62
0.4
128
61
0.5
123
58
0.6
116
55
0.7
113
54
0.8
106
50
0.9
103
48
1.0
97
46
Max. Temperature Recovery
72%
Sensible Effectiveness @70 CFM (32°F):
68%
Sensible Efficiency @70 CFM (32°F):
59%
Sensible Efficiency @67 CFM (-13°F):
56%
VAC @ 60 Hz:
120
Watts / Low Speed:
70
Watts / High Speed:
160
Amp Rating
1.5
HRV 120SRD
HEAT RECOVERY VENTILATOR
# 28 051
2
Summary of Contents for Heat Recovery Ventilator HRV 120SRD
Page 1: ......
Page 3: ...Engineering Data Model HRV 120SRD 3 ...
Page 5: ...Installation 5 ...
Page 6: ...6 Hanging or Mounting the HRV ...
Page 7: ...7 ...
Page 8: ...8 Drain Connections Duct Design and Installation ...
Page 9: ...Partially Dedicated System 9 ...
Page 10: ...Simplified Installation 10 ...
Page 11: ...Fully Dedicated Installation 11 ...
Page 12: ...Optional Controls 12 ...
Page 13: ...Dehumidistat Operation HRV only 13 Defrost Operation Defrost Cycle DIP Switch Settings ...
Page 14: ...Operation 14 Fan speed DIP Switch Settings Electrical ...
Page 15: ...Wiring the Controls 15 ...
Page 17: ...Air Flow Balancing 17 ...
Page 19: ...Troubleshooting 19 ...
Page 20: ...20 Maintenance ...
Page 21: ...21 Wiring Diagrams HRV 120SRD Control Box ...
Page 24: ...24 ...