K60 and KT60 OWNER'S MANUAL

4209-37  04/27/17

Page 2 

Technical support:  1-951-1120        1-800-363-0251          [email protected]

IMPORTANT SAFETY INSTRUCTIONS

 

1. READ AND FOLLOW ALL INSTRUCTIONS.

 
 

2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they

 

    are closely supervised at all times.

 

3. WARNING - To reduce the risk of injury:

 

    a. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving.

 

    b. The steam head is hot. Do not touch the steam head and avoid the steam near the steam head.

 

    c. Prolonged use of the steam system can raise excessively the internal human body temperature 

 

        and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use 

 

        of steam to 10 - 15 minutes until you are certain of your body’s reaction.

 

    d. Excessive temperatures have a high potential for causing fetal damage during the early months 

 

        of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct

 

        exposure.

 

    e. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory 

 

        system problems, or diabetes should consult a physician before using a steambath.

 

    f. Persons using medication should consult a physician before using a steambath since some medi-

 

       cation may induce drowsiness while other medications may aff ect heart rate, blood pressure and 

 

       circulation.

 

4. WARNING - Hyperthermia occurs when the internal temperature of the body reaches a level several 

 

    degrees above the normal body temperature of 98.6 °F (37°C). The symptoms of hyperthermia include

 

    an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The 

 

    eff ect of hyperthermia include:

 

    a. Failure to perceive heat:

 

    b. Failure to recognize the need to exit the steambath:

 

    c. Unawareness of impending risk:

 

    d. Fetal damage in pregnant women:

 

    e. Physical inability to exit the steambath: and

 

    f. Unconsciousness.

 

 

WARNING -

 The use of alcohol, drugs or medication can greatly increase the risk of hyperthermia.

SAVE THESE INSTRUCTIONS

Summary of Contents for K60

Page 1: ...team bath is approximately 10 minutes 6 Pressing the control s on off switch while the steam generator is operating will shut it off 7 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower while in the steam You will find the contrast from water to steam quite invigorating SECTION 1 USING THE K60 KT60 WITH An AMEREC GENERATOR AK STEAM GENERATOR K60 and KT60 ...

Page 2: ...t or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medi cation may induce drowsiness while other me...

Page 3: ...60 and KT60 controls operate identically Bath Time The default bath time is 30 minutes adjustable from 5 to 60 minutes in 5 minute increments A jumper on the steamer board may be set for a bath time settable up to 24 hours max in 1 hour increments To check the time setting turn on the steam bath then press the TIME switch The set time will immediately be displayed Continue holding the switch for 5...

Page 4: ...l either inside or outside the steam room The low volt age KT60 control must be mounted inside the steam room See step 2 above The control cable should already be roughed in to this location a With the decorative cover removed from the control switch assembly insert the two control mounting screws through the control housing you may need to punch through skinned holes and screw a few turns into th...

Page 5: ...age Flushing Procedure The generator should be cool before starting 1 Use the control to start a bath Immediately go to the generator and open the manual drain open is with the handle in line with the drain pipe closed has the handle pointing straight out over the side of the pipe 2 Allow the tank to drain for a couple minutes then close the drain and allow the tank to fill for about 1 minute 3 Op...

Page 6: ...emp 2 Contact Support Control ON Displays Steambath temperature over 132 F 55 C or Sensor faulty 1 If the bath is too hot turn off the circuit breaker and contact Support 2 Treat as E002 Control won t turn OFF Display is ON Control faulty Replace the control Contact Support Control ON Display ON Time Temp display properly Unit Won t steam Unit has not filled completely or Generator is faulty 1 Wai...

Reviews: