 INSTALLATION

 OPERATION

ON/OFF

Press 

 to switch the unit on or off. A buzzer will beep, and the LCD will display 12:00 

o’clock as default.

Setting the clock

Press the 

 button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the 

LCD-display will flash. Press 

 or 

 to adjust the hour. Press 

 momentarily, the 2 right 

digits of the 4 digits will flash. Press 

 or 

 to adjust the minutes of the clock. Press the 

 button for 3 seconds again to activate the clock.

WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours.

This unit can easily be moved from one room to another. In doing so keep this in mind:
– Ensure that the unit is positioned upright, on a level surface and 50 cm away from obstacles.

– To place the loose filters in the filter holder.

 •  Take the filter holder out of the air conditioner
 •  Release the filter fixer and place the active carbon filter (black) and 3M Filtrete™ filter 

(white), where included, in the filter holder.

 •  Place the filter fixer back in the holder.
 •  Place the filter holder back in the air conditioner.

– Do not operate the unit inside the bathroom, shower, or in any other very humid environment.

–  Connect the hose to the unit by turning it clockwise (at least 5 turns). 

–  Similarly, connect the hose to the slide bar connector as far as possible.

–  Place the telescopic slide bar in the open window or door and 

adjust the length to fill as much open space as possible. 

–  Put the slide bar connector in the opening in the telescopic slide 

bar. 

–  Close the window or door as much as possible to prevent outside 

air entering the room.

–  Ensure that the slide bar connector has a free flow outside. 

Important

The flexible exhaust hose can be extended from 660 to 2000 mm for mounting. This length 
has been designed especially according to the specifications of the air conditioner. Do not 
use an extension or exchange for a different hose as that may lead to malfunctioning. The 
exhaust air must flow freely, any blockage can lead to overheating of the air conditioner. 
Take care to prevent any sharp bow or bend in the exhaust.

Summary of Contents for PLMB mono 12KE-410

Page 1: ...PLMB mono blocs PLMB ENGLISH INSTRUCTION MANUAL 9KE 410 12KE 410 15KE 410 PLUS HEATER VERSIONS ...

Page 2: ...able fuse cover that must be refitted when the fuse is replaced In the event of the fuse cover being lost or damaged the plug must not be used until a replacement cover has been obtained If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electr...

Page 3: ...nsed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING Never operate this appliance if it has a damaged cord or plug Do not lead t...

Page 4: ...st hose Water container Remote control Controls ON OFF UP DOWN MODE TIMER SLEEP F SWING AN SPEED Display COOLING FAN HEAT HOURS MINUTES TEMPERATURE Upper air inlet Air outlet Control panel Caster wheels Lower air inlet Exhaust air outlet Cable storage Drainage point with water stopper ...

Page 5: ...r white where included in the filter holder Place the filter fixer back in the holder Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in...

Page 6: ...hing any button on the control panel the backlight will switch on again Heat EH models feature a 1680 W electric heater that can heat a room on cooler days With the mode switch select set the desired temperature and the unit will heat until this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air...

Page 7: ...n to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Programming the timer for OFF when the unit is RUNNING Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead ever...

Page 8: ... add this to your model or wish to purchase a replacement call Amcor for details NOTE The active carbon filter and the 3M Filtrete filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room environment The filter holder on the rear of the unit can be opened The active carbon filter and 3M Filtrete filter can be installed o...

Page 9: ...ge container Replacement filter packages are available directly from Amcor To run the unit without active carbon filter and or 3M Filtrete filter does not do any harm to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The screen filter must always be used 3M and Filtrete are trademarks of the 3M Company Under high humidity conditions it may be necessa...

Page 10: ... decreased then turn on the unit again The remote control does not function Distance too great Make sure the remote control is correctly aimed at the control panel Remote control signal not detected by the control panel The batteries are drained Replace the batteries To correct problems that have not been described in the table and or if the recommended solutions fail to solve the problem contact ...

Page 11: ...ies can be connected only to a supply with system impedance no more than 0 247 Ohm PLMB15KEHx 410 and PLMB15KEx 410 series can be connected only to a supply with system impedance no more than 0 110 Ohm If necessary please consult your supply authority for system impedance information red conform EN 14511 Subject to modifications without prior notice For greater precision please refer to the rating ...

Page 12: ...ired by an unauthorised person The guarantee does not cover accidental damage misuse or consumable items such as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Amcor Limited Amcor Limited disclaims any liability for inciden...

Reviews: