Installation

6

7

Mounting the Exhaust Pipe

•  The supplied Exhaust Hose can be

extended from 1 foot to 5 feet
for mounting. It is recommended that
you use the shortest possible length of Hose.

•  Take care to prevent any kink or

bend in the middle of the Exhaust
Hose, as this will trap hot exhaust air,
which will radiate back into the room.

Cleaning the Filter

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters

and then rinse them thoroughly under running water (no hotter than 104ºF)
Dry thoroughly before replacing.

Notice! Never operate the unit without the filters.

Installation

Window Kit Installation

In order for this unit to function
properly, it must be vented to the
outside.
Fitting the Exhaust Hose through
the window is easy.  Please see
below.
1.  Extend Hose at least 6" and 

insert it into back of the unit,
tightening into place by turning
it clockwise.

2.  Attach Slide Bar Connector, 

(Round Connector) to the 
other end of the Hose by 
extending hose at least 6".  
Then tighten Hose by turning
the (Round Connector) 
clockwise.

3.  Place Adjustable Slide Bar in 

the window and expand so it
fits tightly.

4.  Lower the window.
5.  Make sure the Hose has

no kinks.

Slide Bar has 3 sections which
allows installation in windows up
to 48" in width.

Wall Connection

1. Make a hole (5.1" in diameter)

in the wall.

2. Insert the Round Connector

(part #13) into the hole and

hold in place by using 4 small

screws (not supplied).

3. Extend one end of the Exhaust

Pipe (part #11) and screw into

the Round Connector by

turning clockwise.

4. Extend other end of exhaust

pipe and screw in Adaptor (part

#10) by turning clockwise.

5. Push Adaptor to fit firmly

over the opening on the back

of the unit.

** When not in use, cover the

Round Connector and hole

with Cap (part #14).

Slide Bar

Connector

Round

Connector

WARNING!

The length of the Exhaust Pipe is specially
designed according to the specification of
this product.
Do not replace or extend it with your own hose
as this could cause the unit to malfunction.

Summary of Contents for 000E

Page 1: ... for which it was not designed or 4 repaired or altered in any way that adversely affected its performance or reliability To obtain warranty service the defective product or part must be shipped or delivered to Amcor s authorized service center All postage insurance and shipping charges are the responsibility of the Purchaser and are not included in this warranty AMCOR NEITHER ASSUMES NOR AUTHORIZ...

Page 2: ... and windows are open The filter is dirty Clean or replace filter Air inlet or air Remove blockage outlet is blocked Room temperature lower Lower temperature selected than the selected value The overheat protection Wait 3 minutes until temperature is activated has decreased then turn on again No power supply Make sure outlet works Be sure Green Light is on L C D I Plug Press Re start button Water ...

Page 3: ... cool the unit and make it run more efficiently This is a feature not found in most Portable Air Conditioners If the unit is operated inVERY HUMID air water will collect in the container inside the unit If the Internal Water Container is full the backlight on the LCD display will flash the unit will shut off and it must be drained before it will re start How to Drain the Unit Use a Shallow Contain...

Page 4: ...econd Note When unit is in the following modes Auto Cool or Heat the compressor will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve energy the compressor will not start immediately after a couple degrees increase or decrease but will wait for a 5ºF allowance For example ...

Page 5: ... 2 Attach Slide Bar Connector Round Connector to the other end of the Hose by extending hose at least 6 Then tighten Hose by turning the Round Connector clockwise 3 Place Adjustable Slide Bar in the window and expand so it fits tightly 4 Lower the window 5 Make sure the Hose has no kinks Slide Bar has 3 sections which allows installation in windows up to 48 in width Wall Connection 1 Make a hole 5...

Page 6: ...e is HIGHER than the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heating will resume This machine is equipped with an ANTI FROST function Sometimes while using the heating function during low temperatures the heating will stop for a while to melt the internal frost When this occurs wait for heating to resume As you switch on the h...

Page 7: ...wer Cord When the unit is not in use please store the power cord away as shown in Figure 3 Thank You Thank you for choosing the portable air conditioner from AMCOR a leading brand in indoor air treatment We would like you to enjoy the many benefits this unit offers so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Air Conditioner offers you ...

Reviews: